Input BTU Rating
Natural Gas - 44,000 BTU input at 3.5 in. W.C.
Units after Serial Number Break (VC4GD 481835388,
VC6GD 481835406, VC4GD 541077665) Natural
Gas - 50,000 BTU input at 5.0 in. W.C.
Propane Gas - 44,000 BTU input at 10.0 in. W.C.
Units after Serial Number Break (VC4GD 481835394
& 541077965, VC6GD 481835429) Propane Gas -
50,000 BTU input at 10.0 in. W.C.
Gas Line Pressures
Natural - Recommend (in. W.C.) 7.0, Min 5.0
Natural - Recommend (in W.C.) 8.0, Min 6.0 for Units
after Serial Number Break (VC4GD 481835388,
VC6GD 481835406, VC4GD 541077665)
Propane - Recommend (in. W.C.) 11.0, Min 11.0 (All
Propane Units)
Maximum 14.0 in. W.C. (Nat. or Prop.)
TOOLS
Standard
•
Standard set of hand tools
•
VOM with ability to measure micro amp current
VOM with minimum of NFPA-70E CAT III 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt. Meter leads must also be rated at
CAT III 600V.
•
Gear Puller to remove blower
Special
•
Temperature tester (thermocouple type)
•
Manometer
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - GENERAL
F24682 Rev. D (1016)
Page 6 of 75
Содержание ML-126610
Страница 63: ...Fig 85 VC4G VC6G SERIES FULL SIZE CONVECTION OVENS WIRING DIAGRAMS Page 63 of 75 F24682 Rev D 1016...
Страница 65: ...Fig 87 VC4G VC6G SERIES FULL SIZE CONVECTION OVENS WIRING DIAGRAMS Page 65 of 75 F24682 Rev D 1016...
Страница 67: ...Fig 89 VC4G VC6G SERIES FULL SIZE CONVECTION OVENS WIRING DIAGRAMS Page 67 of 75 F24682 Rev D 1016...
Страница 69: ...Fig 91 VC4G VC6G SERIES FULL SIZE CONVECTION OVENS WIRING DIAGRAMS Page 69 of 75 F24682 Rev D 1016...
Страница 71: ...Fig 93 VC4G VC6G SERIES FULL SIZE CONVECTION OVENS WIRING DIAGRAMS Page 71 of 75 F24682 Rev D 1016...