25
9. Pull the limit bulb out from underneath the fryer tank. (See Fig. 86)
10. Reinstall new high limit by reversing steps 1-9.
REMOVAL OF THERMOPILE (STANDARD MILLIVOLT SYSTEM)
1.
Follow steps 1- 3 under Control Panel (Standard Millivolt Construction)
2.
With a 1/4" socket disengage (4) #8 hex head screws, pull the thermostat wire from the housing and remove
the control housing. (Figs. 27)
Fig. 28
Figs. 27
3.
From the high limit disengage the closed and normally open thermopile wire leads. (Fig. 28)
Содержание GRC25
Страница 61: ...61 SECTION lll WIRING INFORMATION ...
Страница 62: ...62 Drwg No 419357 1 ...
Страница 63: ...63 RS W MILLIVOLT SYSTEM 419999 2 ...
Страница 64: ...64 Drwg No 419357 2 ...
Страница 66: ...66 Drwg No 419357 3 ...
Страница 68: ...68 Drwg No 419322 1 ...
Страница 70: ...70 Drwg No 419322 2 ...
Страница 72: ...72 Drwg No 419322 3 ...
Страница 74: ...74 Drwg No 419323 1 ...
Страница 76: ...76 Drwg No 419323 2 ...
Страница 78: ...78 Drwg No 419323 3 ...
Страница 80: ...80 Drwg No 419318 1 ...
Страница 82: ...82 Drwg No 419318 2 ...
Страница 84: ...84 Drwg No 419318 3 ...
Страница 86: ...86 Drwg No 419340 1 ...
Страница 88: ...88 Drwg No 419340 2 ...
Страница 90: ...90 Drwg No 419340 3 ...
Страница 92: ...92 Drwg No 419337 1 ...
Страница 94: ...94 Drwg No 419337 2 ...
Страница 96: ...96 Drwg No 419337 3 ...
Страница 98: ...98 Drwg No 419564 1 ...
Страница 100: ...100 Drwg No 419564 2 ...
Страница 102: ...102 Drwg No 419564 3 ...
Страница 104: ...104 Drwg No 419366 1 ...
Страница 106: ...106 Drwg No 419366 2 ...
Страница 108: ...108 Drwg No 419366 3 ...
Страница 110: ...110 ...
Страница 111: ...111 ...
Страница 112: ...112 FORM 30912 1 95 ...