F35660
Rev. A (0717)
Page 54 of 5
6
SOLID STATE OR COMPUTER CONTROL HARNESS PIN-OUTS
Pin No.
Input
2
Pin No.
Output
3
E1-1
24VAC Hot
E1-8
24VDC (+) Heat Demand
E1-2
24VAC Neutral
1
E1-9
24VDC (+) Filter
E1-3
Probe
E1-10
24VDC (+) Left Basket Lift
E1-4
Probe
E1-11
24VDC (+) Right Basket Lift
E1-5
Drain Valve Interlock (24VAC) N.O.
E1-12
No connection
E1-6
Ignition Status (24VAC)
—
—
E1-7
Relay DC (-) Common
—
—
NOTES:
1
Connected to ground internally.
2
Input to cooking control.
3
Output to Interface Control Board.
INTERFACE CONTROL BOARD PIN-OUTS
Pin. No.
Input
Pin No.
Output
P1
24VDC Left Basket Lift
P6
Heat Demand Triac (24VAC)
2
P2
24VDC Right Basket Lift
P7
System Ground
P3
24VDC Heat Demand Control
P8
24VAC Left Basket Lift
3
P4
Common Control (-)
P9
24VAC Right Basket Lift
3
P5
Heat Demand Triac (24VAC)
P12
24VAC R1 pump motor relay
P10
Relay Contacts (24VAC)
1
P11
24VAC K3 Filter Relay
NOTES:
1
Relays connected internally.
2
To M1 terminal on gas valve (main).
3
To basket lift relay coils.
FRYMATE (DUMP STATION) WITH OPTIONAL HEATER
Symptom
Possible Causes
No heat.
1.
Unplugged.
2.
Power switch off or inoperative.
3.
Main circuit breaker off or open.
4.
Malfunctioning heater assembly.
GR Series Gas Fryers with NCC Controls (formerly Tridelta / Built after 3/05) - TROUBLESHOOTING