FULL SIZE ELECTRIC CONVECTION OVEN - GENERAL
F25105 (December 2001)
Page 5 of 60
SPECIFICATIONS
Electrical
MODEL
TOTAL
POWER
(KW)
AMPERAGE - 3 PHASE/ 60HZ
PER LINE
1
RECOMMENDED
CIRCUIT
PROTECTION
2
208V
240V
480V
208V
240V
480V
VC4ES
VC4ED
VC4EC
VC6ES
VC6ED
VC6EC
12.5
35
33
15
45
40
20
NOTES:
1. Amperage values in the table are nominal.
Tolerance is +5/-10%.
2. Complied in accordance with National Electric Code,
ANSI/NFPA 70, latest edition.
MODEL
TOTAL
POWER
(KW)
AMPERAGE - 1 PHASE/ 60HZ
PER LINE
1
RECOMMENDED
CIRCUIT
PROTECTION
2
208V
240V
480V
208V
240V
480V
VC4ES
VC4ED
VC4EC
VC6ES
VC6ED
VC6EC
12.5
60
52
26
80
70
35
NOTES:
1. Amperage values in the table are nominal.
Tolerance is +5/-10%.
2. Complied in accordance with National Electric Code,
ANSI/NFPA 70, latest edition.
Содержание 126743
Страница 45: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 December 2001 Page 45 of 60...
Страница 47: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 December 2001 Page 47 of 60...
Страница 49: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 December 2001 Page 49 of 60...
Страница 51: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 December 2001 Page 51 of 60...
Страница 53: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 December 2001 Page 53 of 60...
Страница 55: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 December 2001 Page 55 of 60...
Страница 59: ...FULL SIZE ELECTRIC CONVECTION OVENS TROUBLESHOOTING F25105 December 2001 Page 59 of 60 N O T E S...