background image

               Vtronix

1

TE80SB

Programmable Digital Thermostat

INSTALLATION MANUAL

APPLICATION

The TE80SB Thermostat provides universal replacement of single-stage, 24Vac (20 mA to 1.5A) thermostats
used  in  electric,  gas,  and  oil  heating  and  cooling  systems.  This  thermostat  is  mercury  free  and  requires  no
batteries. The thermostat also can be used to control single stage heat pumps.

The  TE80SB  uses  advanced  proportional  plus  integral  (P+I)  control  for  optimum  temperature  control  and
comfort.

Table 1. Description of  Thermostat.

Model

Mounting

System Selection

Fan Selection

Powering

Method

Backlight

TE80SB

VERTICAL

COOL-OFF-HEAT

ON-AUTO

Power Stealing

Backlight

Fig. 1.Thermostat

FEATURES

-     7-Day programmable with 4 programs/day.
-

 

Stylish design, replaces Honeywell T834C, White Rodgers 1E56 or Lux PSD150.

-

 

LCD display with back lighting lit all the time.

-

 

Power stealing for universal replacement. No common wire required. No batteries.

-

 

Heat cycle rate can be selected (1,3,4,5,6,9,12) by software to suit many heating applications.

-

 

Heating / cooling damper output to control either dampers or heat pump reversing valve.

-

 

User options and set point are retained in the event of lost power.

Содержание TE80SB

Страница 1: ...le 1 Description of Thermostat Model Mounting System Selection Fan Selection Powering Method Backlight TE80SB VERTICAL COOL OFF HEAT ON AUTO Power Stealing Backlight Fig 1 Thermostat FEATURES 7 Day pr...

Страница 2: ...d 1 5 Amp continuous 0 02 to 1 5 A continuous 0 02 to 1 5 A continuous 0 02 to 0 5 A continuous TEMPERATURE RATINGS Temperature setting range Ambient temperature range Shipping temperature range 40 to...

Страница 3: ...as indicated will result in poor temperature control NOTE Level thermostat mounting is for appearance only and is not required for proper thermostat operation Mounting Thermostat Take out the back pl...

Страница 4: ...s used may result in the overheating of the electric heater elements due to improper fan operation The set up switch is an internal switch E F located near the wiring terminals It is used to select pr...

Страница 5: ...the following steps to change each of the settings Each time you press key you will advance to the next operating parameter To go back you must re enter the installer set up as described above INSTALL...

Страница 6: ...l or aggressive For aggressive the system will cool down the room to setting point faster than normal algorithm However an overshoot might be occurred in some situations a Press key to show the coolin...

Страница 7: ...tarts and stop with heating equipment Minimum Off Timer For cooling when the thermostat calls for operation while the minimum off timer is not expired the star symbol keeps flashing Back Lighting The...

Страница 8: ...e Note Default setting can be restored to memory by pressing HOLD and RUN buttons at the same time for 3 seconds Press or key to select desired programming period as below Press PROG to proceed The th...

Страница 9: ...isappeared Set point will be updated to the programmed data Note that only the HOLD button can be used to exit the HOLD temperature CLOCK ADJUSTMENT The clock needs to be adjusted when installed The c...

Страница 10: ...HEAT B terminal will get energized 2 Press key until the set point is higher than room temperature The star symbol is shown on the display The heating equipment is on and terminal W is energized 3 Pre...

Страница 11: ...Note that resistor has to be installed at the fan terminals and not at thermostat terminals To install the Resistor 1 Disconnect power supply 2 Connect the resistor leads to the terminals as shown in...