WIFI+GSM+PSTN
Home Alarm System
Страница 1: ...WIFI GSM PSTN Home Alarm System...
Страница 2: ...mark Device Name Unbind Device 9 9 5 System Status Setting 10 9 6 Zone Setting 10 9 6 1Modify Zone Name 10 9 6 2 Setting Zone Type 11 9 6 3 Add Delete Accessories 11 9 6 4 Turn ON OFF Siren 12 9 7 Add...
Страница 3: ...to set up the alarm system via App Compared with traditional SMS app all the settings can be done on mobile APP This alarm system is widely used in family factories schools shops convenience stores v...
Страница 4: ...s battery is low there will have alarm information promptly pushed to the user s phone Zone name can be modified by users Work with IP Camera the IP Camera APP integrated in the alarm panel APP User c...
Страница 5: ...ight is on and screen show Battery alarm panel is turned on and battery powered Power light is off the alarm panel is not powered Status Status light is on and screen show arm alarm panel is under arm...
Страница 6: ...press S key of the remote control then the alarm panel is under Stay Arming Status When the user walks around at home PIR detector will detect the movement of the human and send signal to alarm panel...
Страница 7: ...e to use alarm system and start searching GSM network GSM signal SIM card and Phone line status in LCD display GSM signal Flashing Means searching GSM signal GSM signal On Means GSM signal normal SIM...
Страница 8: ...ake the alarm system in the status of non warning After disarming the panel would not sound alarm even if you trigger the detectors There are four methods to disarm System Stay Arm It means partial ar...
Страница 9: ...your message at the panel for recording 3 System will record 10 Seconds and then exit automatically or press any key to end whenever your message end 4 Press to exit setting status Add Delete Accesso...
Страница 10: ...te control of different code Delete Detector 1 Press Key to enter setting status 2 Press command 10 01 99 to delete the detectors which added in zone 1 zone 99 Press command 10 to delete all the detec...
Страница 11: ...mpt setting successful and Wifi indicator light keep on 4 Then click Next it will enter to Device List Bind Device 1 After the alarm host connected to WiFi then it will automatic search device 2 Click...
Страница 12: ...ick the device to enter main interface to set Arm Disarm and Stay Arm Zone Setting 1 Modify Zone Name Steps Click Device Setting Click Zone Setting Choose the zone which user wants to Modify Click Mod...
Страница 13: ...one can add 4 detectors Press one of the button between 1 4 alarm host will make Beep Beep voice it means the alarm host is under setting status Trigger the accessories to send signal out Accessories...
Страница 14: ...Apply Button to Save the setting Delete phone No and then click Apply to save the setting 2 Add Delete SMS Phone No Steps Click SMS Phone No and then do the same as add delete alarm phone number Add...
Страница 15: ...Setting Click Time Setting then user can set system time there Timing Setting Click Timing Setting then user can set Alarm Delay Setting Arm Delay Setting etc There also have two groups Timing Arm and...
Страница 16: ...iren ON OFF and Alarm Time 3 Modify Device Password User can reset passed of the device Check push messages Click Messages at the bottom of the right corner then can check all the push messages Note I...
Страница 17: ...xt alarm phone No if user do not press or 2 number key Remark Intercom time is 20s press 3 to intercom for another 20s Remote Phone Call Control User can use telephone or phone to make a call to remot...
Страница 18: ...8686868 2 Remote calling the alarm panel input password to enter setting status input 3113868686868 3 Send SMS message 12343113868686868 Command 3 1 4 Phone No Delete Alarm Phone Number Setting E g De...
Страница 19: ...atus then press 1450 3 Send SMS message 12341450 Command 14 00 99 Keypad Lock ON OFF When turn on keypad password protection user need enter password then can do operations on keypad Default password...
Страница 20: ...60 3 Send SMS message 12345260 Command 52 00 99 seconds Beep Duration Time of Siren Setting Siren beep duration time from 0 20min factory default is 1min E g Set beep duration time as 5min 1 Press on...
Страница 21: ...n be used as eight types defense zone 01 99 Zone numbers 1 5 Zone type 1 Normal Zone 2 Stay Arm Zone 3 Smart Zone 4 Emergency Zone 5 Close Zone 0 1 0 means siren not sound when alarm triggered 1 means...
Страница 22: ...and 67 0 1 SMS Sent ON OFF When Arm Disarm 0 1 0 means OFF 1 means ON E g SMS Sent When Arm Disarm 1 Press on the keypad and then press 681 2 Remote calling the SIM card number input password to enter...
Страница 23: ...need use the new password 0 Arm Send SMS 12341 to set the alarm panel to ARM 1 Stay Arm Send SMS 12342 to set alarm panel to STAY ARM 2 Turn ON Relay Out put Send SMS 12343 to turn on the relay outpu...
Страница 24: ...ample Send SMS 12348001 Front Door Alarm to the alarm panel then replies Zone 01 Front Door Alarm When alarm triggered in zone 01 then alarm panel will sent this SMS to the preset 6 groups SMS phone n...
Страница 25: ...Installation of the Detectors The Installation Diagram of Magnetic Door Detector Caution A The gap between the magnet and the sensor should be less than 10mm B After the installation if the indicate l...
Страница 26: ...he furniture mini escape or any other isolation should be away from the detecting scope E Do not install two or more detectors in the same area or it will cause the interference when alarm F When the...
Страница 27: ...e signal from detectors normally and back up battery work normally or not Detector Inspection A Trigger the detector by hand to check whether it can send the alarm signal successfully or not B Check t...