4.5 - GREEN MACHINE
™
- North America - Installation, Operation, Maintenance, & Troubleshooting Manual
Chapter 4: Control Panel
Page 71
4.3
Alarm Screen Overview
Figure 4-4: Pressure Sensor Alarm shown on the Alarm Screen
The Alarm Screen shows the following - See Figure 4-4:
•
GM Status
•
Normal (Green Box) indicates the GREEN MACHINE is operating normally (no active
Alarms).
•
Alarm (Red Box) indicates an Alarm is active. When an Alarm is active, see Chapter
10, the Operator Instruction Sheet, for directions.
•
Pressure Sensor Alarm:
•
An Alarm will occur:
•
When the Pressure Sensor is not connected to the Control Panel.
•
When the Pressure Sensor is not wired properly at the Control Panel or at the
GREEN MACHINE Internal Junction Box.
•
The GREEN MACHINE will NOT operate during this Alarm.
•
Vacuum Pump Alarm:
•
An Alarm will occur:
•
When there is a problem with the vacuum pump, motor, or circuit.
•
The GREEN MACHINE will NOT operate during this Alarm.