34
20
Too high excitation current! (Err.20)
The load cell excitation current for the specified input is
above approximately 100 mA. Check load cell and wiring for
this input.
21
Too low excitation current! (Err.21)
The load cell excitation current for the specified input is
below approximately 2 mA indicating a cable break. Check
load cell and wiring for this input.
30
Outside accelerometer zero setting
limits! (Err.30)
When trying to zero the Smart box tilt measuring the roll
and/or pitch zero adjustment was to large exceeding 20
degrees. Check that the Smart box is correctly mounted. If
the Smart box is in its correct mounting position (check up
and front indications on the Smart box) it may indicate an
internal Smart box error.
31
Roll or Pitch angle too high! (Err.31)
Smart box roll and/or pitch values exceeding 30 degrees.
See error 30 above for troubleshooting.
80
Meter set-up version error! (Err.80)
There is a mismatch between the setup version of the
parameters stored in the Meter memory and the version
required by the current SW. Likely to occur if SW is
upgraded. Causes the Meter to set the parameters to
default values. After restart the Meter is operational again.
Check Display parameters, Language, Alarm settings,
Printer settings and PIN settings.
81
Meter set-up data error! (Err.81)
There is a check sum error for the set-up parameters in the
Meter. Causes the Meter to set the parameters to default
values. After restart the Meter is operational again. Check
Содержание SI Onboard 9150
Страница 2: ...p n 6190210 Rev B 5 5 21 JG...
Страница 5: ...3 Use this flowchart as a basic guide and reference for setting up your 9150 system...
Страница 36: ......
Страница 41: ......
Страница 45: ...39 10 Technical Data...