RETURN TO INDEX

RECEIVER MOUNTING

PART # 310 124 XXX

5.10

129.54

5.39

136.91

.90

22.86

1.45

36.83

.28

6.99

.15

3.68

R.16  MAX TYP.

4.06

  5.  

RECOMMENDED PANEL

CUTOUT

TOLERANCES ARE:

.XX = .01[.25]

.XXX =  .005[.13]

UNLESS OTHERWISE SPECIFIED

FOR MOUNTING USE

[2.79].11 THRU HOLE,

2-56 OR M2.5 METRIC

TAPPED HOLE

(SUPPLIED WITH 4X, 2-56 SCREWS,

LOCK WASHERS & NUTS)

5 SEE TABLE 1 FOR MINIMUM DISTANCE OF SUBSEQUENT SIDE BY SIDE CUTOUTS.

TABLE 1

PART NUMBER

DESCRIPTION

RECEIVER CUTOUT 

SPACING

410123101

ITA, iCon

1.75 [44.45]

410123102

ITA, iCon, EMI-Shielded

2.20 [55.88]

410123106

ITA, iCon, with Large Cable Clamp

2.20 [55.88]

410123111

ITA, iCon, with Threaded Coupling 

Adapter

2.20 [55.88]

410123116

ITA, iCon, with Large Cable Clamp, 

with EMI Housing and Handle

2.20 [55.88]

410123122

ITA, iCon with Oversized Backshell

2.20 [55.88]

TOOLS REQUIRED

Phillips Head Screwdriver

MOUNTING INSTRUCTIONS

1.  Prepare the mounting surface using the dimensions provided in 

(

Figure A

).

 

2.   Attach the iCon960 receiver to the panel with the provided 2-56 

Phillips head screws and nuts (

Figure B

). Torque screws to 2 in-

lbs [0.23 Nm].

 

 

NOTE:

 If the mounting surface is thicker than 0.125″ [3.18 mm], 

longer screws may be needed.

 

 NOTE:

 If the mounting surface has threaded holes, the nuts will 

not be needed.

 

 NOTE: 

M2.5 hardware can be used in place of the provided 2-56 

hardware.

Figure A. Recommended panel cutout.

Figure B. If you prefer metric hardware, you can replace the 

supplied 2-56 screws with M2.5 hardware.

Dimensions shown: inches [millimeters]

4

Содержание ICON 960

Страница 1: ...IVER MODULE INSTALLATION AND REMOVAL 10 ITA MODULE INSTALLATION AND REMOVAL 11 RECEIVER PROTECTIVE COVER INSTALLATION 12 ITA PROTECTIVE COVER INSTALLATION 13 KEYING PIN KIT ASSEMBLY 14 TROUBLESHOOTING...

Страница 2: ...ront and rear of the receiver are shown in Figure B The front has a polarizing feature which prevents the ITA and receiver from being engaged upside down The front of the receiver can be identified as...

Страница 3: ...mates with the receiver The front has a polarizing feature which prevents the ITA and receiver from being engaged upside down Wires exit the ITA through the two 30 cable clamp exit NOTE The ITA enclos...

Страница 4: ...OTE For optimum performance and system longevity distribute the contact load evenly DISENGAGEMENT INSTRUCTIONS 1 Turn the engagement handle 180 to the open position 2 Remove the ITA Figure A Ensure th...

Страница 5: ...A iCon with Threaded Coupling Adapter 2 20 55 88 410123116 ITA iCon with Large Cable Clamp with EMI Housing and Handle 2 20 55 88 410123122 ITA iCon with Oversized Backshell 2 20 55 88 TOOLS REQUIRED...

Страница 6: ...ION A Installing the cover while the iCon960 ITA is disengaged from the receiver or the ITA is in the disengaged position Figure A OPTION B Installing the cover while the iCon960 ITA is engaged to the...

Страница 7: ...ead screwdriver Figure B 5 Tighten the captive screws at the top and bottom of the ITA securing the enclosure to the ITA OPTION B ENGAGED POSITION 1 Place the cover onto the ITA as shown in Figure C T...

Страница 8: ...iring 2 Remove the engagement handle by pulling it upward 3 Loosen the captive screws with a Phillips head screwdriver Figure B The removable enclosure has two captive screws located at the top and th...

Страница 9: ...g 1 5 screws alternate screws when tightening 2 Install 375 screws to mount clamp to ITA frame Slowly alternate tightening the 1 5 screws until the clamp has cinched the wire s or cable s tightly NOTE...

Страница 10: ...in the frame Install modules so that Pin 1 is located at the top of the receiver frame Figure A 2 Using a Phillips head screwdriver tighten the top screw 1 2 full turns while pushing lightly against...

Страница 11: ...Using a 5 32 Allen wrench tighten the top screw while applying light pressure to the face of the module 5 Maintain pressure while tightening the bottom screw 6 Repeat this sequence until the module is...

Страница 12: ...lign the center boss of the iCon 960 protective cover with the center bushing on the receiver Figure A 2 Push the cover on ensuring that the center boss mates properly with the center bushing 3 Press...

Страница 13: ...lace the cover on the engagement mechanism Figure A 3 When the engagement handle is in the up open position it will accept the protective cover using the center boss Figure A 4 Turn the engagement han...

Страница 14: ...receiver 2 Secure the keying pin with the 2 56 Phillips head screws 3 Remove the iCon 960 ITA cover 4 Place the other keying pin in the corresponding location in the ITA 5 Replace the ITA cover NOTE I...

Страница 15: ...tacts ITA frame does not line up when engaging with receiver This may indicate that the ITA was dropped and is out of alignment or that a module is not mating with its intended module Remove and inspe...

Отзывы: