background image

G6 & G10 USER MANUAL

VPC

3/16/21

 

For more information visit vpc.com

RETURN TO INDEX

9

PRECAUTIONARY NOTES

Never probe a contact without using a mating patchcord as a test lead.

Never forcefully engage a system if there is an excessive amount of resistance on the handle.

Never allow an ITA to drop as this may cause misaligned engagement and/or irreparable damage.

Always insert and extract a contact insertion/extraction tool in-line with the contact. Never apply pressure to the side as this may
break either contact or tool.

When engaging the ITA with the receiver, caution must be taken to ensure that the ITA is parallel with the receiver upon engagement
and that the ITA rollers are engaged 

at the same time!

It is advisable that power to the interface system be disconnected prior to handling and maintenance.

Caution should always be used when engaging, making sure that all foreign objects are removed from the system.

50 OHM ITA contacts engaged with 75 OHM receiver contacts will damage 75 OHM contacts.

Use care when hinging a receiver down. Always maintain hand contact to prevent receiver from dropping suddenly,

resulting in damage to the system.

TROUBLESHOOTING

ITA engagement bearings/studs are not lining up with the engagement slots of the receiver

Check the alignment of the ITA Frame. There is a possibility that the ITA Frame will have misaligned itself if it was dropped.
Contact VPC - user adjustments to system, unless authorized, will void warranty.

Forceful engagement of the receiver and the ITA will result in serious damage to multiple parts of the system (modules, receiver, ITA
and contacts).

ITA frame is not lined up when engaging with receiver

May indicate ITA was dropped and is out of alignment or a module is not mating properly. Remove and inspect the ITA for damage.
Contact VPC - user adjustments to system, unless authorized, will void warranty.

Check for foreign objects/tools that may be obstructing proper engagement.

Verify the orientation of the receiver and ITA modules.

Inspect the mating modules to ensure they match. Power ITA module is mating with power receiver module, etc.

Forceful engagement of the receiver and the ITA will result in serious damage to multiple parts of the system (modules,
receivers, ITA and contacts).

Excessive force is needed upon engaging the handle

Damaged contact(s) can cause noticeable resistance when trying to engage and mate. Inspect all contacts for damage. If a
contact is replaced, the mating contact on the opposite side should also be inspected and replaced if necessary.

Follow all steps above for an unaligned ITA frame, if force is still needed please contact VPC for assistance.

ITA will not engage with the receiver after diagnosing the above problems

Contact VPC - user adjustments to the system, unless authorized, will void the warranty.

No continuity upon engagement

If replacing a contact on the ITA, the mating contact on the receiver side should also be inspected and replaced if necessary.

Check wiring - replace if necessary.

Check that all contacts are secured in modules.

Verify that any 50 OHM ITA contacts are not engaged with 75 OHM receiver contact. This will damage the 75 OHM contact.

Any 75 OHM ITA contact engaged with 50 OHM receiver contact will not create continuity/contact.

A “short” in the wiring upon engagement

A damaged contact(s) can cause noticeable resistance when trying to engage and mate. Inspect all contacts for damage. If a
contact is replaced, the mating contact on the opposite side should also be inspected and replaced if necessary.

Check wiring - replace if necessary.

Receiver and ITA will not disengage

This may indicate that the engagement mechanism within the receiver is faulty - contact VPC immediately. User adjustments to
system, unless authorized, will void the warranty.

Содержание 410 104 272

Страница 1: ...WINGS 6 G6 RECEIVER MOUNTING SPECIFICATIONS 7 G10 RECEIVER MOUNTING SPECIFICATIONS 8 G10 RECEIVER PANEL CUT OUT DRAWING 9 PRECAUTIONARY NOTES TROUBLESHOOTING G6 G10 USER MANUAL 3 2 21 Please note that any printed or downloaded User Manuals may not reflect the most current revisions The information contained in these manuals is subject to change For the most current information available visit vpc ...

Страница 2: ...e backshells slide up to provide access to wires and connectors To slide the backshell up be sure to first remove the screw s located at the base of the ITA The G10 has two screws at the base and the G6 has one Once the backshell is put back in place be sure to secure the screw s back in place as the EMI shielding provided by the backshell will not take effect otherwise 1 For drawings specs and mo...

Страница 3: ...y for engagement with the receiver The receiver should be checked one last time for any foreign objects that may hinder engagement With the ITA in the upright position and the receiver handle open align guide pins with bushings on the ITA and mate The handle may now be moved to the upright closed position to engage contacts CAUTION When engaging the ITA with the receiver caution must be taken to e...

Страница 4: ...A INSTALLED SCREW C INSTALLED PIN B OPEN PIN D OPEN SCREW B INSTALLED SCREW D INSTALLED PIN B INSTALLED PIN D INSTALLED SCREW B OPEN SCREW D OPEN PATTERN 2 PATTERN 5 RECEIVER ITA RECEIVER ITA PIN A INSTALLED PIN C OPEN SCREW A OPEN SCREW C INSTALLED PIN A OPEN PIN C INSTALLED SCREW A INSTALLED SCREW C OPEN PIN B INSTALLED PIN D OPEN SCREW B OPEN SCREW D INSTALLED PIN B INSTALLED PIN D OPEN SCREW B...

Страница 5: ... or three oblong cable exits G10 for example each exit will hold a maximum of 683 signal 20 AWG wires OR 202 coax RG316 wires Formula to calculate approximate number of one wire type that will fit in each cable exit N D d 1 2 907 N Number of Wires D Diameter of Converted Oblong Bushing d Outside Diameter of Wire General Guidelines Wire Type Outside Diameter of Wire d Number of Wires N 20 AWG Signa...

Страница 6: ...e information visit vpc com RETURN TO INDEX G6 G10 VERTICAL HINGED MOUNTING FRAME VERTICAL HINGED MOUNTING FRAME G10 5U PART 310 113 342 VERTICAL HINGED MOUNTING FRAME G6 5U PART 310 113 341 5 G10 5U PART 310 113 342 G6 5U PART 310 113 341 ...

Страница 7: ...G6 G10 USER MANUAL VPC 3 16 21 For more information visit vpc com RETURN TO INDEX 6 RECEIVER MOUNTING SPECIFICATIONS G6 RCV PART 310 104 318 ...

Страница 8: ...G6 G10 USER MANUAL VPC 3 16 21 For more information visit vpc com RETURN TO INDEX MOUNTING SPECIFICATIONS RECEIVER G10 10 MODULE PART 310 104 317 7 ...

Страница 9: ...G6 G10 USER MANUAL VPC 3 16 21 For more information visit vpc com RETURN TO INDEX PANEL CUTOUT RECEIVER G10 10 MODULE PART 310 104 317 8 ...

Страница 10: ...or damage Contact VPC user adjustments to system unless authorized will void warranty Check for foreign objects tools that may be obstructing proper engagement Verify the orientation of the receiver and ITA modules Inspect the mating modules to ensure they match Power ITA module is mating with power receiver module etc Forceful engagement of the receiver and the ITA will result in serious damage t...

Отзывы: