background image

9050 USER MANUAL

VPC

07/19/2022

For more information visit vpc.com

RETURN TO INDEX

12

8-32 x .625" PLATFORM 

MOUNTING SCREWS

9050TR PLATFORM REMOVAL AND REINSTALLATION

PART # 310 104 369

TOOLS REQUIRED

5

/

32

  Ball End Allen Wrench or Ball Driver

Phillips Head Screwdriver
Zip Ties

REMOVAL 

1. 

Secure receiver to rack using the captive 10-32 mounting screws 
(

Figure A

). The platform should only be removed from the receiver 

after the receiver has been secured to the rack. 

2. 

Remove any optional accessories including keyboard tray, leg kit, and 
instrument bracket. 

3. 

With the receiver secured to the rack, remove the six 8-32 mounting 
screws from the bottom of the 9050TR to remove the platform (

Figure 

B

). 

4. 

Remove the 8-32 screws that attach the platform brackets to the 
slides. The platform will now be free from the receiver and slides.  The 
platform brackets do not need to be removed from the platform for 
transportation. 

5. 

To secure the slides for transport, return the slides to the closed 
position and use zip ties to secure the 3 sections of each slide.

Figure A. 

 

Figure B. 

The six mounting screws must be removed from the receiver 

before the platform can be removed.

Figure C. The brackets will be securely attached to the slides after the mounting 

screws are installed.

REINSTALLATION 

1. 

Remove the zip ties used to secure the slides. 

2. 

Attach the platform with brackets to the slides using six 8-32 
mounting screws (

Figure C

). 

3. 

Slide the platform to the closed position and install the 
six 8-32 mounting screws to re-attach the platform to the 
receiver.  

4. 

Reinstall any of the optional accessories. 

5. 

Once the platform has been re-attached to the receiver 
and slides, detach the receiver from rack by unscrewing the  
captive 10-32 mounting screws.   

Platform removal is recommended for safe transport should the rack 

need to be moved or relocated. 

Содержание 310 104 368

Страница 1: ...ION REGARDING U HEIGHT 9 INSTALLING INSTRUMENT BRACKET 10 INSTALLING KEYBOARD TRAY 12 9050TR PLATFORM REMOVAL REINSTALLATION 13 9050TR HANDLE ROTATION SIDE CHANGE 14 MICROSWITCH REMOVAL INSTALLATION 1...

Страница 2: ...ies to forming and enlarging tools It is advisable that power to the interface system be disconnected prior to handling and maintenance Caution should always be used when engaging making sure that all...

Страница 3: ...S REQUIRED Phillips Head Screwdriver INSTALLATION INSTRUCTIONS 1 Install clip cage nuts on rack to correlate with mounting holes and captive screws on receiver 2 Place receiver up to clip cage nuts on...

Страница 4: ...8 10 32 x 1 mounting screws Figure A Tighten screws in a cross pattern to ensure even torque is applied 3 Using the 6 receiver mounting holes on the front of the Vertical Hinged Mounting Frame VHMF at...

Страница 5: ...onnect to instrumentation and allow for slides to fully extend without putting tension on the cables 2 Install both sets of slides using manufacturer s instructions included with slide packaging or on...

Страница 6: ...slides to the back of the receiver using the 4 receiver rack mounting screws provided 6 Pull the platform receiver out as far as possible The slides will lock in position Push the blue tabs located o...

Страница 7: ...or this length of slide with the inclusion of a longer instrument bracket SLIDE INSTALLATION 1 The height and weight of the 9050 and 9050TR require the use of 2 sets of slides for full support Determi...

Страница 8: ...e instrument bracket instructions also in this User Manual 9050 INSTALLATION 1 Install inner slides back into slide kits in the rack 2 Attach the receiver mounting flanges to the inner slide rails on...

Страница 9: ...ART 310 104 369 310 104 402 310 104 483 With certain receivers including the 9050 9050TR the slide mechanism protrudes downward slightly into the next U height on both sides of the receiver Please mak...

Страница 10: ...groove Push the inner slide in about 6 8 inches and then pull out the right side Slide the track of the mid section over the right side of the inner slide Pull the slide out until the position matches...

Страница 11: ...DTRAY PART 310 113 439 MOVEMENT 12 INCH SLIDE 1 2 30 48 KEYBOARD WITH TOUCHPAD KEYBOARD TRAY 12 INCH SLIDES MOUNTING BRACKET RIGHT MOUNTING BRACKET LEFT USB KEYBOARD CONNECTOR RUBBER GROMMET 13 0 330...

Страница 12: ...e rack Fully extend the keyboard slides to access the hole locations Figure B 3 Insert the keyboard into the keyboard tray Wrap the plastic strain relief around the cable near the back of the keyboard...

Страница 13: ...slides The platform brackets do not need to be removed from the platform for transportation 5 To secure the slides for transport return the slides to the closed position and use zip ties to secure th...

Страница 14: ...wrench 2 Remove the handle and reposition in 90 increments Figure A 3 Replace the screw and tighten until the handle is secured tightly SWITCHING HANDLE SIDES 1 Using the 3 32 Allen wrench remove the...

Страница 15: ...aining screws using a Phillips screwdriver removing each as they are loosened caution should be used so that the screw s do not fall into the system 4 Carefully remove the microswitch for continuity t...

Страница 16: ...ll available options for the 9050 and 9025 ITA TOOLS REQUIRED 3 mm Allen Wrench Phillips Head Screwdriver STANDARD ENCLOSURES 1 To mount ITA frame align frame with enclosure 2 Insert screws and tighte...

Страница 17: ...8 N O I T I S O P E L M M O D U L E P O S I T I O N 20 N 5 I T I S O P E L U D O M O M O D U L E P O S I T I O N 1 M D U L E P O S I T I O N 23 O D L E P O S I T I O N 14 O U M 13 N O I T I S O P E L...

Страница 18: ...the warranty No continuity upon engagement When replacing an ITA contact the mating contact on the receiver side should also be inspected and replaced if necessary Check wiring and replace if necessa...

Отзывы: