Table 1
– Turnstile operating mode
Turnstile
operating
mode
number
Number
of short beeps after
pressing the BUT button
Turnstile operating mode
0 (simple
press)
Reboot (the mode is similar to turning the
turnstile on/off)
1
1
Factory reset:
- pulse control mode of the turnstile
- the turnstile enters the STOP mode after
being switched on
-
the turnstile enters the “ANTIPANIC” mode
when controlled using the ACS, after the AP
and GND terminals get connected
- the turnstile is controlled by the control
panel, the status of the buttons is
transmitted to ACCESS OUT outputs (p.
5.4)
2
2
- switching between the pulse and potential
control modes of the turnstile (p. 5.3)
3
3
- the turnstile enters the mode of free
passage to the left after being switched on.
4
4
- the turnstile enters the mode of free
passage to the right after being switched on.
5
5
-
activation of the “ANTIPANIC” input after
the
AP
and
GND
terminals
are
closed/opened
6
6
Disabling/enabling of the control panel
7
7
Possibility to switch the relay terminals into
hold or passage counting mode, in
“ANTIPANIC” mode
8
8
- test mode for checking the turnstile
performance
5.1 Power connection
DO NOT:
USE THE POWER SUPPLY UNITS WITH AN OUTPUT CURRENT BELOW
5.0 A.