![Vonsch Quatrofrem Series Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/vonsch/quatrofrem-series/quatrofrem-series_configuration-and-diagnostics_1049784096.webp)
UNIFREM v.3.41x
10 May 2017
Page 96 from 180
Name [ID]
Description
Def.
LS1 Mask [896]
The limit switch command will be active if at least one of the selected binary
inputs or logical blocks will be active.
Look choises of parameter's Bit1 DS mask [553] (page 55)
LS2
Group of parameters number [877]
Second limit switch setting
MENU \ SETTINGS \ FUNCTIONS \ LIMIT SWITCHES \ LS2
Name [ID]
Description
Def.
LS2 Type [881]
Limit switch type setting. Configuration possibilities are the same as in LS1
LS1 Type [880] (page 95).
Look choises of parameter's LS1 Type [880] (page 95)
LS2
Frequency
[916]
Maximum frequency restriction value when activation the limit switch function
set to the "Decelerating" type. Decelerating function will be applied only for the
given rotation direction according to the limit switch type.
0,00
Hz
÷
LS2 Torque [1181]
The value of maximum torque during the activation of Limit switch set to
"Weakening". Weakening is activated for positive or negative torque,
according to the "For reverse" value.
0,0 Nm
Min.
8
÷
8
Value depends on the parameter
Source of the torque reverse [922]
(str. 53). For
the choice
„
According to the setpoint value
“
is from -(
(str. 65)), for
(str. 65).
LS2 Track [885]
Range track that the converter allows to pass when activating the limit switch
function set to the Track + Stop type. Both parameters Transmission ratio
[888] (page 47) and Wheel circumference [889] (page 47) need to be set.
0,0000
m
0,0000
m
÷
99000,0000 m
LS2 Source [898]
Limit switch source setting
None
Look choises of parameter's Quick stop source. [986] (page 49)
LS2 Mask [899]
The limit switch command will be active if at least one of the selected binary
inputs or logical blocks will be active.
Look choises of parameter's Bit1 DS mask [553] (page 55)
LS3
Group of parameters number [878]
Third limit switch setting
MENU \ SETTINGS \ FUNCTIONS \ LIMIT SWITCHES \ LS3
Name [ID]
Description
Def.
LS3 Type [882]
Limit switch type setting. Configuration possibilities are the same as in LS1
LS1 Type [880] (page 95).
Look choises of parameter's LS1 Type [880] (page 95)
LS3
Frequency
[917]
Maximum frequency restriction value when activation the limit switch function
set to the "Decelerating" type. Decelerating function will be applied only for the
given rotation direction according to the limit switch type.
0,00
Hz
÷
LS3 Torque [1182]
The value of maximum torque during the activation of Limit switch set to
"Weakening". Weakening is activated for positive or negative torque,
according to the "For reverse" value.
0,0 Nm
Min.
8
÷
Value depends on the parameter
Source of the torque reverse [922]
(str. 53). For
the choice
„
According to the setpoint value
“
is from -(
(str. 65)), for
Содержание Quatrofrem Series