55
Maintenance: Freshwater system
Coolant. Mixture
WARNING!
All glycol is hazardous and harmful
to the environment. Do not consume!
Glycol is flammable.
IMPORTANT!
Ethylene glycol must not be
mixed with other types of glycol.
Mix:
40 % “Volvo Penta Coolant” (conc. coolant)
60 % water
This mixture protects the engine against internal cor-
rosion, cavitation and frost damage down to - 28 °C
(-18°F). (Using 60 % glycol lowers the freezing point
to -54 °C (-65°F)). Never mix more than 60 %
concentrate (Volvo Penta Coolant) in the cooling
liquid, this will give reduced cooling effect and
increase the risk of overheating, and will give reduced
freezing protection.
IMPORTANT!
Coolant must be mixed with
pure
water, use
distilled - de-ionized water
. The wa-
ter must
fulfill the requirements specified by
Volvo Penta, see “Water quality”.
IMPORTANT!
It is extremely important that the
correct concentration of coolant is added to the
system. Mix in a separate, clean vessel before
adding into the cooling system. Ensure that the
liquids mix properly.
Water quality
ASTM D4985:
Total solid particles ...................................... < 340 ppm
Total hardness: ............................................ < 9.5° dH
Chloride ......................................................... < 40 ppm
Sulfate ........................................................... < 100 ppm
pH value ........................................................
5,5– 9
Silica (acc. ASTM D859) .............................. < 20 mg SiO
2
/l
Iron (acc. ASTM D1068) .............................. < 0.10 ppm
Manganese (acc. ASTM D858) ................... < 0.05 ppm
Conductivity (acc. ASTM D1125) ................ < 500 µS/cm
Organic content, COD
Mn
(acc. ISO8467) .... < 15 mg KMnO
4
/l
Содержание D3-110i
Страница 1: ...OPERATOR SMANUAL D3 130A D3 160A D3 190A D3 110i D3 130i D3 160i D3 190i ...
Страница 103: ......
Страница 104: ...7745859 English 12 2005 ...