Specifications

4

Model                                                                     VIVA 30

CAPACITY
INPUT

      

Voltage
Voltage Range

OUTPUT 

 

Voltage Regulation (Inv. Mode)
Waveform

BATTERY

Battery Type & Number
Floating Charge Voltage
Typical Recharge Time

PHYSICAL

Dimension (DxWxH mm)
(@ vertically stand)
Net Weight (kgs)

                           30 W

228 x 82.5 x 207

2.7                            3.1

  13.7V ±1.5%

4 hours recover to 90% capacity

230 VAC

100-300 VAC

160-230 VDC +/-10%

DC Output

12 V 7 Ah x 1              12 V 9 Ah x 1

2

Product Overview

Front View:

Back View:

1

2

3

4

Output receptacles              
AC input                               External battery connectors

Input fuse

3

4

1
2

Quick Guide

V.1.0

Viva Inverter

Introduction

VIVA is a compact inverter designed to power 
Its portable size features easy installation and high 

movability. It’s perfect for 

diverse applications from indoor to outdoor events or activities such as camping
and night markets.

Besides, it can accept wide input voltage range. It’s perfect to use in unstable power 
area. I

t also offers flexible display ways: vertically stand, flatly display, and two-

direction mounting.  It’s very easy to install at home, office, or carry outside. 
C

ompared to heavy-duty inverters, it’s a cost-effective solution for lighting.  

 

energy saving bulbs up to 3-4 hours. 

1

3

Before using the unit, please read all instructions and cautionary 
markings on the unit, this manual and the batteries.

Important Safety Warnings

General Precaution-

Conventions used:
WARNING! 

Warnings identify conditions or practices that could result in personal 

                    injury; 

CAUTION!  

Caution identify conditions or practices that could result in damaged to 

                    the unit or other equipment connected.

CAUTION!

 This unit contains more than one live circuit (batteries & AC line). Power

                  may be present at more than one source. To reduce the risk of electrical
                  shock, disconnect both AC and DC power from the unit before attempting
                  any maintenance or replacement inside of the unit. Turning off the unit
                  will not reduce this risk. 

CAUTION! 

To reduce risk of injury, only use qualified batteries from qualified 

                  distributors or manufacturers. Any unqualified batteries may cause 
                  damage and injury. Do NOT use old or overdue batteries. Please check 
                  the battery type and date code before installation to avoid damage and 
                  injury.

WARNING! 

It's very important for system safety and efficient operation to use

                    appropriate external battery cable. To reduce risk of injury, external 
                    battery cables should be UL certified and rated for 75 C or higher. And 
                    do NOT use copper cables less than 18AWG. Below is the external battery 
                    cable reference according to system requirements.

 

     Model                  Typical Amp.      1-4 Feet (one-way)           Dia-mm
   VIVA 30                       3 A                        AWG 14                    1.6277

Table 1  Minimum Recommended Battery Cable Size versus Length

WARNING!

 Provide ventilation to outdoors from the battery compartment. The 

                    battery enclosure should be designed to prevent accumulation and 
                    concentration of hydrogen gas at the top of the compartment.

CAUTION! 

Use insulated tools to reduce the chance of short-circuit when installing 

                   or working with the inverter, the batteries, or other equipments attached 
                   to this unit. 

CAUTION! 

For battery installation and maintenance, read the battery manufacturer's 

                   installation and maintenance instructions prior to operating.

1

3

4

    Power switch
Status indicators 
(please see the Operation section for the details)
    Line mode/Charging mode indicator - green LED
    Inverter mode indicator - Yellow LED
    Alarm indicator - Red LED

1

2
3

4

2

Personnel Precaution - 

CAUTION!

 If you need to remove a battery, make sure all accessories are off so 

                  you don’t cause a spark.

CAUTION!

 Make sure the area around the battery is well ventilated.

CAUTION! 

Careful to reduce the risk or dropping a metal tool on the batteries. 

                  It could spark or short circuit the batteries and could cause an explosion.

CAUTION! 

Remove personal metal items such as rings, bracelets, necklaces, and 

                  watches when working with batteries. Batteries can produce a short 
                  circuit current high enough to make metal melt, and could cause severe 
                  burns.

CAUTION!

 Avoid touching eyes while working near batteries.

CAUTION!

 Have plenty of fresh water and soap nearby in case battery acid contacts 

                   skin, clothing, or eyes.

CAUTION! 

NEVER smoke or allow a spark or flame in vicinity of a battery.

CAUTION! 

If a remote or automatic generator start system is used, disable the 

                   automatic starting circuit or disconnect the generator to prevent 
                   accident during servicing.

Отзывы: