C H A P T E R 1 0
–
S P E C I F I C A T I O N S
AT5600 User Manual 98-119 issue 14
Page 227
10.2.19.
GBAL Test
The measurement accuracy is based on the chosen test conditions, and is given
by
𝐴
𝑇
= 𝐴
𝑅
+ 0.87(𝐴
𝐶
+ 𝐴
𝑉𝐼
+ 𝐴
𝑉𝑂
)
where:
A
T
is the total accuracy (dB)
A
R
is the basic relative accuracy
A
C
is the calibration accuracy
A
VI
is the correction for the input voltage level
A
VO
is the correction for the output voltage level
where:
𝐴
𝑅
= 0.5 𝑑𝐵
𝐴
𝐶
= 0.1 + (0.000001 ∗ 𝐹
𝑀
)
dB
𝐴
𝑉𝐼
=
0.01 𝑑𝐵
𝑉
𝑀𝐼
𝐴
𝑉𝑂
=
0.01𝑑𝐵
𝑉
𝑀𝑂
where:
F
M
is the test frequency (Hz)
V
MI
is the measured input voltage (V)
V
MO
is the measured output voltage (V)
Содержание AT5600
Страница 10: ...AT5600 User Manual 98 119 issue 14 Page 10 16 4 AT Series Server Software 437...
Страница 39: ...C H A P T E R 2 S Y S T E M O V E R V I E W AT5600 User Manual 98 119 issue 14 Page 39...
Страница 88: ...C H A P T E R 6 S A F E T Y S Y S T E M S AT5600 User Manual 98 119 issue 14 Page 88...
Страница 168: ...C H A P T E R 7 T E S T S A N D T E S T C O N D I T I O N S AT5600 User Manual 98 119 issue 14 Page 168...
Страница 198: ...C H A P T E R 8 F R O N T P A N E L O P E R A T I O N AT5600 User Manual 98 119 issue 14 Page 198...
Страница 204: ...C H A P T E R 9 T R O U B L E S H O O T I N G AT5600 User Manual 98 119 issue 14 Page 204...
Страница 252: ...C H A P T E R 1 0 S P E C I F I C A T I O N S AT5600 User Manual 98 119 issue 14 Page 252...
Страница 258: ...C H A P T E R 1 2 W A R R A N T Y A N D S E R V I C E AT5600 User Manual 98 119 issue 14 Page 258...
Страница 270: ...C H A P T E R 1 3 T E S T F I X T U R E S AT5600 User Manual 98 119 issue 14 Page 270...