C H A P T E R 1 0
–
S P E C I F I C A T I O N S
AT5600 User Manual 98-119 issue 14
Page 212
10.2.4.
TR Test
The accuracy is based on the chosen test conditions, and is given by:
𝐴
𝑇
= 𝐴
𝑅
+ 𝐴
𝐶
+ 𝐴
𝑃𝑉
+ 𝐴
𝑆𝑉
+ 𝐴
𝑁
where:
A
T
is the total accuracy (%)
A
R
is the basic relative accuracy (%)
A
C
is the calibration accuracy (%)
A
PV
is the correction for primary voltage level (%)
A
SV
is the correction for secondary voltage level (%)
A
N
is the correction for the turns ratio (%)
where:
𝐴
𝑅
= 0.1 %
𝐴
𝐶
= 0.1 % + (0.00001 % ∗ 𝐹
𝑀
)
𝐴
𝑃𝑉
= 0.1 % + (
0.01 %
𝑉
𝑃𝑀
)
𝐴
𝑆𝑉
= 0.1 % + (
0.01 %
𝑉
𝑆𝑀
)
𝐴
𝑁
= 0.1 % + (
0.1 %
𝑁
𝑀
)
where:
F
M
is the test frequency (Hz)
V
PM
is the measured primary voltage (V)
V
SM
is the measured secondary voltage (V)
N
M
is the measured turns ratio (Primary/Secondary)
Содержание AT5600
Страница 10: ...AT5600 User Manual 98 119 issue 14 Page 10 16 4 AT Series Server Software 437...
Страница 39: ...C H A P T E R 2 S Y S T E M O V E R V I E W AT5600 User Manual 98 119 issue 14 Page 39...
Страница 88: ...C H A P T E R 6 S A F E T Y S Y S T E M S AT5600 User Manual 98 119 issue 14 Page 88...
Страница 168: ...C H A P T E R 7 T E S T S A N D T E S T C O N D I T I O N S AT5600 User Manual 98 119 issue 14 Page 168...
Страница 198: ...C H A P T E R 8 F R O N T P A N E L O P E R A T I O N AT5600 User Manual 98 119 issue 14 Page 198...
Страница 204: ...C H A P T E R 9 T R O U B L E S H O O T I N G AT5600 User Manual 98 119 issue 14 Page 204...
Страница 252: ...C H A P T E R 1 0 S P E C I F I C A T I O N S AT5600 User Manual 98 119 issue 14 Page 252...
Страница 258: ...C H A P T E R 1 2 W A R R A N T Y A N D S E R V I C E AT5600 User Manual 98 119 issue 14 Page 258...
Страница 270: ...C H A P T E R 1 3 T E S T F I X T U R E S AT5600 User Manual 98 119 issue 14 Page 270...