VPN
98-121
ISSUE
3
PAGE
13
2 Fit an AC Power Cord with the second cable gland supplied with the Banner AC Interface Box.
Do not tighten at this point. Refer to Figure 3
Figure 3
3)Remove the lid from the Banner AC Interface Box.
4) Identify the terminal block, P1, P2, and P5, inside the Banner AC Interface Box. Also identify
the EDM slide switch.
Model Number EZAC-R9-QE8.
5) Fit the cable gland for the AC Power Card onto the bottom hole of the Banner AC Interface
Box.
Connect the flying leads of the AC Power Cord to terminal block P5 inside the AC Interface Box.
Tighten the cable gland after connections are made. Refer to Figure 4
AC Power
Terminal Block P5
AC Power Cord Wire Color
Earth
1
Green-Yellow or Green
Neutral
2
Blue or White
Line
3
Brown or Black
Figure 4