TECHNICAL DATA 

a) Ambient air indicator
General 

Operating voltage ..........................................16 V/DC
Display ...........................................................LED  (7-segment)
Measured values ...........................................Carbon dioxide, temperature and relative humidity
Operating ambient temperature .....................0 °C to +40° C 
Ambient temperature during storage .............-20 °C to +60° C 
Ambient air humidity ......................................0% to 95% relative air humidity, not condensing
Dimensions ....................................................297 x 210 x 50.5 mm (W x H x D)
Weight ...........................................................approx. 2.4 kg

Carbon dioxide sensor

Measurement range ......................................0 – 3000 ppm
De

fi

 nition ........................................................1 ppm (0 - 1,000 ppm)

 

5 ppm (1001 - 2000 ppm)

 

10 ppm (2001 - 3000 ppm)

Accuracy ........................................................+/- 70 ppm or +/- 5% of the reading
 

(>2000 ppm: ±7% of the reading)

Repeatability ..................................................±20  ppm
Temperature in

fl

 uence ...................................±2 ppm of the reading, relative to +25 °C

Air pressure in

fl

 uence ....................................±0.13% of the reading

Warming-up phase ........................................<60 s at +22 °C

Temperature sensor

Measurement range ......................................0 °C to +40° C 
De

fi

 nition ........................................................0.1 °C

Accuracy ........................................................±1  °C

Humidity sensor

Measurement range ......................................20% to 90% relative humidity
De

fi

 nition ........................................................1%

Accuracy ........................................................±5% relative humidity at +23 °C

b) Power adaptor

Operating voltage ..........................................100 - 240 V AC, 50-60 Hz
Output ............................................................16 V/DC, 1.25 A

GETTING STARTED

a) Connecting the mains adapter, switching on the meter

Connect the low-voltage plug of the provided mains adapter to the corresponding socket (6) on the ambient 
air indicator. Then connect the mains adapter with the cable provided  to the mains outlet of the public 
power supply.
Turn on the ambient air indicator via the on/off switch (5) (position “I”). All display segments appear brie

fl

 y.

b) Warm-up phase 

After it is turned on, the ambient air indicator is in the warm-up phase; this lasts at most 60 seconds at an 
ambient temperature of +22 °C. During this time, the ambient air indicator cannot display reliable results 
on the display. 

c) Measuring carbon dioxide levels, temperature and relative humidity 

After the warm-up phase (max. 60 s), the ambient air indicator is in automatic measurement mode. The 
carbon dioxide content is shown in the upper display (7) in ppm, the room temperature in the display to the 
lower left (10), and the room humidity in the display to the lower right (11).

 

The correct display of the carbon dioxide content is also dependent on the air circulation in the 
room; it can take a few minutes for the display to stabilise. The same is true for the display of the 
temperature and humidity.

 

For a CO

2

 content >3000 ppm, “Hi” is shown in the display.

 

 In the display area for the humidity, „Lo“ appears for a humidity <20% and „Hi“ for a humidity >90%.

d) Air quality display in traf

fi

 c light colours 

The air quality is displayed via a traf

fi

 c light display with 3 coloured LEDs. The following displays are 

possible: 
Green:   The CO

2

 content is less than 800 ppm. The air quality is good.

Yellow:  

The CO

2

 content is between 800 and 1500 ppm. Air quality is ok. Ventilating the room soon is 

recommended.   

Red:  

The 

CO

2

 content is more than 1500 ppm. Air quality is bad. The room needs to be ventilated.  

CLEANING AND MAINTENANCE

The device requires no servicing on your part apart from occasional cleaning.
Use a soft, antistatic and lint-free cloth for cleaning. Do not use abrasive or chemical cleaners.
Do not apply too much pressure on the display, to avoid scratch marks.

DISPOSAL 

   Electronic devices are recyclable waste materials and must not be disposed of in the household 

waste! Dispose of an unserviceable product in accordance with the relevant statutory regula-
tions. 

Содержание CO-500

Страница 1: ...k nnen Ein erh hter CO2 Gehalt f hrt zu M digkeit Konzentrationsschw che und Leistungsverlust Der Qualit tsstatus wird als Ampelanzeige gr n gelb rot dargestellt Gleichzeitig wird die Lufttemperatur...

Страница 2: ...Sie die Raumluft Anzeige ber den Ein Ausschalter 5 ein Schalterstellung I Es erscheinen kurz alle Displaysegmente b Aufw rmphase Nach dem Einschalten befindet sich die Raumluft Anzeige in der Aufw rm...

Страница 3: ...oom air in order to take appropriate early measures for ventilation An increased CO2 level leads to fatigue lack of concentration and loss of efficiency and performance The quality level is displayed...

Страница 4: ...let of the public power supply Turn on the ambient air indicator via the on off switch 5 position I All display segments appear briefly b Warm up phase After it is turned on the ambient air indicator...

Страница 5: ...opri e correspondante en temps utile Une teneur lev e en CO2 cause de la fatigue des troubles de concentration et une baisse de performance De plus un indicateur lumineux vert jaune rouge indique le s...

Страница 6: ...e arr t 5 position I Tous les segments d affichage apparaissent bri vement b Phase de mise temp rature Apr s la mise en service l indicateur d air ambiant se trouve en phase de mise temp rature celle...

Страница 7: ...uate maatregelen voor het luchten te kunnen nemen Een verhoogd CO2 gehalte leidt tot vermoeid heid concentratie en prestatieverlies De kwaliteitsstatus wordt als stoplicht groen geel rood weergegeven...

Страница 8: ...el de omgevingsluchtindicator via de aan uit schakelaar 5 een schakelstandaard I aan Er verschijnen korte displaysegmenten b Opwarmfase Na het inschakelen bevindt de omgevingsluchtindicator in de opwa...

Отзывы: