EU Declaration of Conformity (DoC)
Company name
Voltaware Services Limited
Postal address
282 Earls Court Road
Postcode and City London, UK, SW5 9AS
Telephone
+44 (0) 20 74601521
E-Mail address
We declare that the DoC is issued under our sole responsibility and
belongs to the following product:
Apparatus model:
VOLTA1P
Product Type:
Energy Monitor
Code no.
1PEU001
Hardware Revision 1.5
The object of the declaration described above is in conformity with the
relevant Union harmonisation legislation:
Directive 2014/53/EU
The following harmonised standards and
technical specifications have been applied:
Health & Safety (Directive 2014/53/EU Art. 3.1(a))
EN 60950-1
2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013
EN 61010-1
2010 (3rd Edition)
EN 62311
2008
EMC (Directive 2014/53/EU Art. 3.1(b))
EN 301 489-1 V2.1.1
EN 301 489-17 V3.1.1
EN 61326-1
2013
Radio Spectrum (Directive 2014/53/EU Art. 3.2)
EN 300 328
V2.1.1
Signed for and on behalf of Voltaware Services Limited
London, 13/04/2018
Rishabh Jaipuria
COO
Warning!
•
Voltages dangerous to human health are involved in the
installation of the Voltaware Energy Monitor. Follow all
warnings provided in this pamphlet to ensure your own
safety.
•
A qualified electrician must install the Voltaware Energy
Monitor. Voltaware will not be held responsible for failure to
follow these guidelines.
•
Do not install the Energy Monitor if the mains supply voltage
is outside of the nominal operating voltage range.
•
You should never, under any circumstances, install or allow
your Voltaware Energy Monitor to be installed with the mains
electricity switched on. There is a risk of explosion, fire and
electric shock if this is ignored.
•
Installation must comply with electrical standards and
approved codes of practice for the country or region where
the installation is taking place.
•
The incoming cables feeding the main switch (marked 'X' in
Fig. 3) always remain connected to the mains even when
the switch is turned OFF. This means that the 'source'
terminals (see terminals on the upper side) are always live.
Do not attempt to connect the line and neutral magnetic
connectors to these inputs. Connect the connectors on the
load side of the main circuit breaker (see terminals on the
lower side). These outputs are always inactive when the
main switch is off.
•
Do not tamper with the installation of the Energy Monitor
while the mains electricity is switched on.
•
Do not dispose of in fire.
•
Do not allow the Energy Monitor to come into contact with
water.
•
Do not leave the Energy Monitor in direct sunlight or near
sources of heat.
•
Do not install the Energy Monitor if you see any apparent
damage on the transceiver, cable or its parts.
Single Phase Energy Monitor
Installation guide
single
phase
1
2
3