EU Declaration of Conformity (DoC)

Company name 

Voltaware Services Limited

Postal address 

282 Earls Court Road

Postcode and City  London, UK, SW5 9AS
Telephone 

+44 (0) 20 74601521 

E-Mail address 

[email protected]

We declare that the DoC is issued under our sole responsibility and 

belongs to the following product:
Apparatus model: 

VOLTA1P

Product Type: 

Energy Monitor

Code no. 

1PEU001

Hardware Revision  1.5

The object of the declaration described above is in conformity with the 

relevant Union harmonisation legislation:

Directive 2014/53/EU

The following harmonised standards and 

technical specifications have been applied:

Health & Safety (Directive 2014/53/EU Art. 3.1(a))

 

EN 60950-1 

2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013

 

EN 61010-1 

2010 (3rd Edition)

 

EN 62311 

2008

EMC (Directive 2014/53/EU Art. 3.1(b))

 

EN 301 489-1  V2.1.1

 

EN 301 489-17  V3.1.1

 

EN 61326-1 

2013

Radio Spectrum (Directive 2014/53/EU Art. 3.2)

 

EN 300 328 

V2.1.1

Signed for and on behalf of Voltaware Services Limited

London, 13/04/2018

 

Rishabh Jaipuria

 COO

Warning!

• 

Voltages dangerous to human health are involved in the 

installation of the Voltaware Energy Monitor. Follow all 

warnings provided in this pamphlet to ensure your own 

safety.

• 

A qualified electrician must install the Voltaware Energy 

Monitor. Voltaware will not be held responsible for failure to 

follow these guidelines.

• 

Do not install the Energy Monitor if the mains supply voltage 

is outside of the nominal operating voltage range.

• 

You should never, under any circumstances, install or allow 

your Voltaware Energy Monitor to be installed with the mains 

electricity switched on. There is a risk of explosion, fire and 

electric shock if this is ignored.

• 

Installation must comply with electrical standards and 

approved codes of practice for the country or region where 

the installation is taking place. 

• 

The incoming cables feeding the main switch (marked 'X' in 

Fig. 3) always remain connected to the mains even when 

the switch is turned OFF. This means that the 'source' 

terminals (see terminals on the upper side) are always live. 

Do not attempt to connect the line and neutral magnetic 

connectors to these inputs. Connect the connectors on the 

load side of the main circuit breaker (see terminals on the 

lower side). These outputs are always inactive when the 

main switch is off.

• 

Do not tamper with the installation of the Energy Monitor 

while the mains electricity is switched on.

• 

Do not dispose of in fire.

• 

Do not allow the Energy Monitor to come into contact with 

water.

• 

Do not leave the Energy Monitor in direct sunlight or near 

sources of heat.

• 

Do not install the Energy Monitor if you see any apparent 

damage on the transceiver, cable or its parts.

Single Phase Energy Monitor

Installation guide

single

phase

1

2

3