INSTALLATION INSTRUCTIONS

VOLT

®

 Floodlight with Motion Sensor

VFL-40XX-MS-ABZ

[email protected] • 813.978.3700

Infrared (IR) Sensor (Continued)

Max 39.4 Ft.

180

Ma

x 39.4 Ft.

1.64 Ft.

6.56~11.48 Ft.

3

2

1

Last, turn on the power and check if the lighting fixture works.

Detection distance: max. 39.4 feet 

Detection angle: 180°

Optimal installation height: 

6.56 - 11.48 feet

Operating humidity:< 93% RH

1.  LUX: 0-2000 lux twilight sensor 

sensivity adjustable.

a.  When set at maximum 

(towards the sun) the 

motion sensor works even in 

the day time. 

b.  When set at minimum 

(towards the moon) the 

motion sensor works only in 

the dark.

2.  TIME: From 7 sec to 15 min. adjustability

a.  At the maximum setting, the fixture is illuminated 15 minutes 

after the sensor is triggered.

b.  At the minimum setting, the fixtured is illuminated 7 seconds 

after the sensor is triggered. 

3.  SENS: If the sensor is too sensitive or not sensitive enough, it can be 

adjusted here.

Replace IR Sensor

1

Remove Backing with IR Sensor

Rotate the bracket so that 

the backing can easily be 

removed from the fixture.

Remove the backing with IR 

sensor from the fixture by 

loosening the screws.

Use pliers to squeeze the 

connectors and release 

wires.

Bracket

Backing

Fixture

Screw

IR Sensor

Supply Cable

Connectors

Wires

2

Remove/Replace IR Sensor

Unscrew the lock screw from 

the knuckle and remove the 

IR sensor from the back of 

the fixture.

Place the wires of the 

replacement IR sensor inside 

of the back by passing wires 

through the knuckle. Then, 

connect the replacement 

sensor to the back by using 

the previously removed lock 

screw. Hand tighten until 

snug.

Back

IR Sensor

Supply Cable

Lock Screw

Wires

Содержание VFL-40 MS-ABZ Series

Страница 1: ... MS ABZ INSTALLATION INSTRUCTIONS Specifications and product details subject to change without notice Copyright 2019 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST 1 ...

Страница 2: ...atts 25 AMPS at 12 volts 4 Underground Low Energy Cable must not be buried over 6 15 2 cm in order to connect to the main low voltage cable 5 Wiring connections must be made with wire connectors that is suitable for outdoor use 6 Position the wire connector so that it is located within 6 inches 15 2 cm from a building structure a luminaire or fitting INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR IN...

Страница 3: ...mounting surface Place a mark on the wall using the holes of the mount These marks will be used for the wall anchors Wall Anchors Hole Wall Drill the holes for the wall anchors using the marks on the wall Insert the wall anchors into the drilled holes Tighten the hex nuts on the bolts until they are secure to the wall INSTALLATION INSTRUCTIONS 10W Flood Light 30W Flood Light 8 25 4 25 7 35 8 85 8 ...

Страница 4: ...fixture to your desired orientation and tighten set screws with a wrench Adjust the IR sensor to proper orientation After installation but before power is on A Check whether the lighting fixture is firmly fixed B Check whether wires are connected properly Infrared IR Sensor max 11 48 Ft min 6 56 Ft This product can be installed outdoors It is recommended to install in these orientations to protect...

Страница 5: ...nated 15 minutes after the sensor is triggered b At the minimum setting the fixtured is illuminated 7 seconds after the sensor is triggered 3 SENS If the sensor is too sensitive or not sensitive enough it can be adjusted here Replace IR Sensor 1 Remove Backing with IR Sensor Rotate the bracket so that the backing can easily be removed from the fixture Remove the backing with IR sensor from the fix...

Страница 6: ...ectors with pliers to engage crimp connectors Back Fixture IR Sensor Supply Cable Connector Wires Brown Wire from Sensor Black Wire from Supply Cable Connector Red Wire from Sensor Blue Wire from Sensor Red Wire from Luminaire Black Wire from Luminaire White Wire from Supply Cable 4 Make Connections of IR Sensor Wires Carefully tuck all the wires inside of the back housing Place the backing with t...

Страница 7: ... without notice Copyright 2019 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 w w w v o l t l i g h t i n g c o m IS VFL 40XX MS ABZ ver1 pdf Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST ...

Отзывы: