41.VW.2210.3102_BA_V00_EN
VAS 681 003A
39
EN | Operation
Information parameters
The “
Information parameters
” submenu contains all operating parameters, fault messages
and device actions grouped together. All actions performed on the high-voltage DC charger
are recorded and stored here.
The parameters in this menu serve as the basis for maintenance intervals and fault
diagnostics and cannot be changed.
Navigate through the parameters by pressing function keys F2 (down) and F3 (up).
Exit the parameter menu by pressing function key F1 (exit).
Parameter
Meaning
Unit
Versions
Software versions of the components
Documentation
Access to the latest operating manual. The QR code shown
here is also on the product.
Scan the QR code with a mobile device to access the latest
operating manual.
QR code
Serial number
Serial number of the product
MAC-Address
Unique network address
Total time
Total operating hours elapsed
h
Standby time
Standby time in hours without a charging process
h
Charging time
Time taken to deliver the charging power
h
Chg. time
Service
Time which is reset during servicing
h
Charge
Total ampere hours delivered
Ah
Energy
Total energy delivered
kWh
Charge count
Number of real charging processes measured
Total mating
cycles
Total number of connector mating cycles
Mating cycles
Number of mating cycles for the DC plug
Cold starts
Number of device starts by connecting the power supply
plug
Warm starts
Number of starts from standby mode
AC relay cycles
Number of closing cycles for the AC relay
DC relay cycles
Number of closing cycles for the DC relay
Temp. AC Max
Maximum temperature at the AC measuring point
°C
Temp. DC Max
Maximum temperature at the DC measuring point
°C
Temp. CCS Max
Maximum temperature at the charging plug
°C