Volkswagen VAS 6558A/38 Скачать руководство пользователя страница 6

 

11.VW.2210.2485_BA_V02_EN 

VAS 6558A/38 

 

EN | Safety 

 

 

WARNING

 

Danger of fatal electric shock 

The electrical voltage in the product is dangerous and can cause serious injury or death from electric 
shock. 
Defective and damaged products cannot guarantee protection against electrical voltage. 

 

Do not let the product come into contact with chemicals! 

 

Replace a defective or damaged product immediately! 

 

Never attempt to repair or tamper with the product! 

 

 

Intended use 

Use the product only in accordance with this operating manual; otherwise the electrical hazard protection 
provided by the product can no longer be guaranteed. 
The product is used to adapt the VAS 6558/VAS 6558A high-voltage measurement module to the vehicle-side 
plug connection specified by the vehicle manufacturer in the guided fault finding. 
The product is equipped with safety resistors and is suitable for the following measurements: 

 

Certified test for de-energized circuit according to the manufacturer’s specifications 

 

Insulation resistance measurement 

(only permitted with measuring device with max. DC 1000 V, 2 mA!)

 

 

Continuity measurement 

(only permitted with measuring device with max. DC 60 V, 1 A!)

 

The product may be used only for adapting HPK connectors. 
In this operating manual, vehicle manufacturers are exclusively defined as vehicle manufacturers in the 
Volkswagen Group. 
Any use beyond what is listed here is prohibited.  

Requirements for the target group 

Only qualified personnel may work with this product! 
In this operating manual, qualified personnel is defined as personnel meeting all requirements for working 
on high-voltage systems applicable in the country of operation, as defined by: 

 

Regulations applicable in the country of operation 

 

Qualification according to DGUV 200-005 level 2 or higher, or equivalent 

 

Specifications from the vehicle manufacturer and/or the operator. 

At all times while using the product, staff must wear the personal protective equipment prescribed by the 
vehicle manufacturer for work on high-voltage systems. 

Duties of the operator 

The operator is responsible for ensuring that all staff working with the measurement adapter fulfills the 
requirements for the target group. 
The operator is also responsible for ensuring that the following conditions are met: 

 

The measurement adapter is always in perfect working order. 

 

The regular inspection intervals for the measurement adapter are observed and recorded. 

 

 

 

Содержание VAS 6558A/38

Страница 1: ...11 VW 2210 2485_BA_V02_EN VAS 6558A 38 1 Operating manual High voltage measurement adapter VAS 6558A 38...

Страница 2: ...duction or reprinting whether in whole or in part always requires the written permission of the manufacturer Copyright TRANSLATION OF THE ORIGINAL OPERATING MANUAL All rights reserved All text images...

Страница 3: ...ing levels 5 Important safety instructions 5 Intended use 6 Requirements for the target group 6 Duties of the operator 6 PRODUCT DESCRIPTION 7 Scope of delivery 7 Design 7 Symbols and connections 8 Co...

Страница 4: ...tate of the art for working with high voltage systems Validity of the declaration of conformity The declaration of conformity applies to the product described in the operating manual Any changes modif...

Страница 5: ...y instructions CAN result in minor physical injury Important safety instructions This chapter contains the safety instructions that must be observed when handling the product DANGER Danger of fatal el...

Страница 6: ...t only permitted with measuring device with max DC 60 V 1 A The product may be used only for adapting HPK connectors In this operating manual vehicle manufacturers are exclusively defined as vehicle m...

Страница 7: ...condition of the product and the completeness of the delivery If anything is missing or defective please contact the manufacturer immediately 1 High voltage measurement adapter 2 USB stick with opera...

Страница 8: ...tive and accessible parts in accordance with VDE 0100 Part 410 412 1 The disposal instructions prohibit disposal of the product with household waste Always dispose of the product in accordance with al...

Страница 9: ...for HPK connectors see the Design section Separate test sockets are assigned to this connection area Connection area for HPK connectors a Sockets for double HPK connectors The sockets are connected t...

Страница 10: ...0 V 2 mA Protection class II double insulated Weight 275 g Dimensions L H W 125 mm 90 mm 50 mm Ambient conditions Operation Storage Transportation Temperature 0 C to 50 C 20 C to 60 C 20 C to 60 C Ele...

Страница 11: ...sparks and electric arcs Never disconnect high voltage plug connections while under load Do not use the product in potentially explosive atmospheres Ensure that the product is at least 50 cm above the...

Страница 12: ...ns Use only a dry cloth to clean the product Storage Store the product in a dry and dust free location when not in use Disposal Observe the safety instructions Always dispose of the product in accorda...

Страница 13: ...nd workmanship Further information on the warranty conditions can be found in the terms and conditions on the manufacturer s website Customer service Always include the item number and if available th...

Страница 14: ...vision Stand 03 2022 Volkswagen Aktiengesellschaft K GVO LW Group After Sales Group Service Literature and Systems Repair Shop Equipment PO box 011 4915 38442 Wolfsburg Germany For internal use only S...

Отзывы: