12.VW.2210.1026_BA_V01_EN
VAS 6558/9-4
1
Operating manual
High-voltage test adapter VAS 6558/9-4
Страница 1: ...12 VW 2210 1026_BA_V01_EN VAS 6558 9 4 1 Operating manual High voltage test adapter VAS 6558 9 4...
Страница 2: ...er in whole or in part always requires the written permission of the manufacturer Copyright TRANSLATION OF THE ORIGINAL OPERATING MANUAL All rights reserved All text images and graphics are subject to...
Страница 3: ...ons 6 Intended use 7 Requirements for the target group 7 Duties of the operator 7 PRODUCT DESCRIPTION 8 Scope of delivery 8 Design 8 Symbols and connections 9 Wiring diagram 10 Technical data 11 OPERA...
Страница 4: ...fety requirements and the state of the art for working with high voltage systems Validity of the declaration of conformity The declaration of conformity applies to the product described in the operati...
Страница 5: ...g manual is only valid for the following product Item number 22101026 Designation High voltage test adapter VAS 6558 9 4 Warning levels This chapter provides information about the warning levels used...
Страница 6: ...ock The electrical voltage in high voltage systems is lethal and can cause death by electric shock Liquids condensation and high humidity can cause short circuits Do not let the product come into cont...
Страница 7: ...d here is prohibited Requirements for the target group Only qualified personnel may work with this product In this operating manual qualified personnel is defined as personnel meeting all requirements...
Страница 8: ...is missing or defective please contact the manufacturer immediately 1 High voltage test adapter 2 USB stick with operating manual Design Product design 1 Plug high voltage cable 2 Socket air condition...
Страница 9: ...with household waste Always dispose of the product in accordance with all local disposal regulations The CE marking certifies that the product complies with all applicable European regulations and ha...
Страница 10: ...58 9 4 10 EN Product description The product has the following connection areas TP1 TP2 Each connection area has the following test sockets Connector Function Ground socket Positive socket Negative so...
Страница 11: ...e insulated Weight 1325 g Dimensions L H W 180 mm 120 mm 55 mm Cable length 850 mm Ambient conditions Operation Storage Transportation Temperature 5 C to 40 C 20 C to 60 C 20 C to 60 C Elevation above...
Страница 12: ...l and will cause death by electric shock Use the product only on high voltage systems and components that have been certifiably de energized WARNING Danger of fatal electric shock The electrical volta...
Страница 13: ...connection you want to test 3 Lock the connection 4 Connect the plug to the disconnected socket of the connection you want to test 5 Lock the connection 6 Connect the high voltage measurement module...
Страница 14: ...the plug to the disconnected socket of the connection you want to test 3 Lock the connection 4 Connect the high voltage measurement module to the high voltage test adapter according to the guided fau...
Страница 15: ...e product in potentially explosive atmospheres Ensure that the product is at least 50 cm above the ground during operation The plug connections have an automatic locking mechanism To detach a plug con...
Страница 16: ...ly a dry cloth to clean the product Storage and transportation Store the product in a dry and dust free location when not in use Disposal Observe the safety instructions Always dispose of the product...
Страница 17: ...al material and workmanship Further information on the warranty conditions can be found in the terms and conditions on the manufacturer s website Customer service Always include the serial number with...
Страница 18: ...58 9 4 18 Volkswagen Aktiengesellschaft K GVO LW Group After Sales Group Service Literature and Systems Repair Shop Equipment PO box 011 4915 38442 Wolfsburg Germany For internal use only Subject to t...