Specified torques
Component
Specified torque
Bolts -1- on combustion chamber
4 Nm
7.10
Removing and installing glow plug for
heater - Q9-
Note
♦
Glow plug with flame monitor - Q9- is activated immediately
after activation and switched off again about 1 minute after a
flame has been detected.
♦
The maximum glow period for the Airtronic »D3« is 150 sec‐
onds.
♦
When heater unit is switched off, glow plug with flame monitor
- Q9- is switched back on again during the 4 minute run-on
time to burn off all fuel.
♦
It is essential to check the mantle for carbonised deposits and
damage if glow plug with flame monitor - Q9- is renewed.
Removing
Note
♦
Special tool for removing glow plug with flame monitor - Q9-
is supplied.
♦
It is essential to check the mantle for carbonised deposits and
damage if glow plug with flame monitor - Q9- is renewed.
– Cut through cable ties -1-.
– Remove intermediate piece -2-.
– Remove upper part of outer shell -item 1-