5.5
Engine
Control routine before start to run:
-
Check the oil level: with oil temperature up to 70°C, stop the engine and wait 2 minutes, then check
the oil dipstick. The oil level must be at the top of the marked zone.
-
Check the water level before start.
-
With the engine running, check that there is not any oil, water or fuel leakage.
-
Check the fan functionality. Operating range 92°C to 87°C.
Maintenance routine:
-
Change the engine oil and oil filter at the indicated mileage.
-
Engine spare parts must be from VW group original parts, detailed on the VW Golf GTI TCR parts
catalogue.
-
Use always the fluids detailed above, User Manual point 5.4.
-
Clean and check the air filter at least once per event. At urban circuits, clean or replace it more
frequently. It is recommended to have two or three air filters and replacing it during the weekend.
Changing it is strongly recommended in case of rain.
-
Check that the alternator belt is clean and that there are not small stones inside the Poly-V.
-
Clean the radiator and intercooler panel often.
-
If any doubt, contact VWMOSP service.
-
Check that the seals are in good conditions, if a replacement is needed contact VWMOSP
Parts subject to frequent service:
Engine
Torque
Remarks
Oil drain plug
By hand
Oil filter plastic cover
25 Nm
Oil filter
Moisten the “O” ring
Spark plug
28 Nm
Use only original VWMS parts
For detailed parts substitution information download the Workshop Manual from our web.
5.6
Air filter
Standard air filter cleaning procedure:
1.
Remove the air filter from the car and plug opening to throttle body with a clean rag to stop any crud
getting where it shouldn't.
2.
Disassemble filter assembly by removing the four small screws at the bottom (intake side) of the
outer-body and pull out the filter element.
3.
Tap the filter gently to dislodge the larger debris that have collected, do not use compressed air as
you could damage the paper elements.
4.
Apply detergent to the filter. Squirt the fluid down the elements from the outside while holding the
filter at an angle over a bucket. Don't re-distribute the detergent that's collected in the bucket
through the filter again.