are applicable for an engine temperature of at least 80°C
⇒
display group 1, display zone 4.
Test procedure
– Start engine and run at idling speed.
– Connect vehicle diagnostic tester, and select engine control
– Select diagnosis function “011-Read measured value block”.
Note
The “Display group 1” is an example to illustrate the procedure.
– Select “Display group 1”.
Indicated on display: (1…4 = display zones)
Note
The display zones may be shown one below the other or next to
each other on the display of the vehicle diagnostic tester.
– To change to another display group proceed as follows:
Display group
Button
Higher
Press
↑
button
Lower
Press
↓
button
Skip
Press
←
button.
If the specifications are attained in all display zones:
– Exit diagnosis function.
– Switch off ignition.
6.3
Evaluating measured value blocks at
idling speed
Always follow safety precautions
.
.
Display group:
◆
1 - Injected quantity
◆
,
◆
3 - Exhaust gas recirculation
,
◆
4 - Activation of injectors -N30...N33-
◆
7 - Temperatures
,
◆
10 - Air quantities
,
◆
11 - Charge pressure control
◆
,
◆
13 - Smooth running control
◆
,
◆
Display group 1
1 2 3 4
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
6 Measured value blocks, engine codes CPYA, CPYB, CPYC, CPYD, CPYE, CPYF, CPYG
111