6
7
0800 4 VOGAL (0800 486 425)
E:
W:
www.rataequipment.com
0800 4 VOGAL (0800 486 425)
E:
W:
www.rataequipment.com
INSTALLATION
Pre-start Checks
1.
Ensure that the towball on the vehicle is compatible with the spreader.
The spreader is designed to accept a 1-7/8” diameter towball.
2.
Check the operation of all controls.
3.
Check the tyre pressure (10psi minimum - 25psi maximum, dependant
on load size).
4.
Check the condition of the tyres. Look for signs of wear, cuts and impact
damage.
5.
Check the free operation of the shutter lever.
6.
Check the condition of the hopper and lid.
7.
Check that all grease points have been greased.
8.
Check the gearbox for oil leaks, if an oil leak is evident do not use the
spreader and carry out repairs immediately.
9.
Check that the agitator is movable, free from debris and well greased.
OPERATION
Operating
1.
Before filling the hopper, set the flow from the hopper to the desired
position by moving the lever (A) to the setting required (B) and locking it
into place with the tri knob (C).
2.
Place the shutter lever (A) in the zero position and fill the hopper with the
material to be spread.
3.
Drive to the area requiring the fertiliser, engage the D pin (D) to the
IN
position and re-lock the D pin to engage the drive. Obtain desired
spreading speed and open shutter lever (A) until lever hits the stop (C).
4.
It is important to remember that a constant speed ensures a constant
spread width. When turning, turn clockwise in order to maintain a
constant spinner speed.
A.
B.
C.
D.