Secti
o
n
2
–
In
stallati
o
n
(
En
gin
ee
rs P
ro
cedu
re)
6
Warning!
If your Freshbrew or B2C machine is connected to a water supply and used
without a water filter as specified above, your warranty will be void.
3.
Connect the flexi-hose supplied with your machine to the stopcock ensuring that the
seal is fitted correctly. Flush the water supply before connecting the machine.
N.B.
When connecting your machine to a water supply always use a new flexi-hose
(such as the one supplied). Never re-use an existing hose.
4.
Connect the hose to the inlet valve located on the rear of your machine. Ensure that
the seal is correctly fitted. Ensure that all water supply fittings are tight.
5.
Turn on the water supply at the stop tap and check for leaks. Prime the water filter
(where fitted) following the instructions supplied by the filter manufacturer.
2.3 Connecting the Electrical Supply
Safety First!
The electrical safety of this appliance can only be guaranteed if it is correctly and
efficiently earthed, in compliance with National and European regulations on
electrical safety. Always ensure that the earthing is efficient. If you have any doubts,
contact a qualified technician to check the system.
The manufacturer declines all liability for damage resulting from a system which has
not been earthed. On no account should it be earthed only to the water supply pipe.
The appliance must be connected to mains protected by a certified safety switch
(double pole) with a capacity appropriate for the application and in compliance with
National and European regulations on electrical safety.
The appliance must be connected to a 230 Volt 50Hz 13 amp fused switched socket
outlet, installed to the latest edition of the IEE regulations, using a 3 pin BS approved
13 amp fused plug for UK and in compliance with National and European regulations
on electrical safety in other countries
Important:
If the mains lead becomes damaged in any way it must be replaced by a
special lead available from the manufacturer.
2.4 Commissioning Procedure
A trained installation engineer must carry out the following procedure before your machine can
be used for the first time. Ensure that the electrical and water services to the machine are
connected correctly. Check for leaks in the water supply.
1.
Open the front door of your machine.
2.
Ensure that the waste bucket is fitted correctly. Clip the level detector and overflow
pipes correctly onto the rim of the bucket.
3.
Cup Turret. Remove the lid and fill the tubes with the correct size cups for the cup
catcher type fitted to your machine. Allow the cups to drop into the tubes directly
from the packaging. DO NOT touch the cups with your hands.
Содержание PR14037000
Страница 1: ...1 Part Number PR14037000 Issue New December 2011 ...
Страница 65: ...61 ...
Страница 66: ...62 ...
Страница 67: ...63 ...
Страница 68: ...64 ...