2.0 Installation Requirements
The information in this section is very important for
proper operation of the compressor. Read these
requirements before beginning installation.
Before installing the compressor, examine the possible locations and
consider the following factors when selecting a location:
•
it is convenient for making electrical, hydraulic and air
connections and does not require extensive plumbing
•
hose and wire lengths will be the shortest possible and a
minimum number of 90 degree fittings will be used
•
the oil level at the sight glass can be checked easily
•
there will be sufficient clearance around the unit for good air
circulation and effective cooling
•
it can be serviced easily without having to disconnect lines or
remove and reposition the unit
•
it will be protected from excessive exposure to the elements
and possible incidental damage from other operations
•
it is away from heat sources such as engines, exhaust
systems or other components that generate heat
•
it is not in a location where it will be exposed to high
contamination levels, including combustible gases
2.1 Ventilation Requirements
During operation, the PREDATAIR60 can develop
considerable heat, as much as a house furnace.
Proper ventilation is vital for proper operation and to
avoid damage to components.
If you are installing the compressor into a new
configuration, refer to section 5.0 Testing Ventilation for
information
.
2.1.1 Top Mounting
This is the preferred mounting location. Placing the unit on top of
the service body (Figure 3) provides the best access to ambient
air and provides the best cooling. Maintain a minimum of 6”
between the sides of the compressor housing and all other solid
objects
!