INSTALLATION

1.  Screw wall brackets to the wall. See relevant drawing for setting 

out dimensions on the reverse page. These are given to the outside 
edge of the bracket.

2.   Ensure the brackets are level and in line with each other, use slots 

for adjustment.

3.   Holding the heat shield at the edges lift and drop onto the wall 

brackets. Ensure that the panel is the correct way up with the 
bottom of the panel having a greater gap.

4.  Check the heat shield is seated correctly onto the wall brackets.

CLEANING AND HANDLING

Enamel surfaces must be treated as glass, with care and attention.

To clean enamel surfaces simply wipe over with a dry cloth or soft 
brush. Abrasive pads and scouring cleaners must not be used as these 
will damage the finish. Care should be taken not to knock the enamel 
with hard objects as it will chip.

SAFE DISTANCES

A

Minimum distance of 95mm from rear of appliance to face 
of  panel  for  appliances  up  to  7kW  in  accordance  with 
HETAS guidelines.

Charnwood Stoves

Vlaze  heatshields  have  been  fully  tested  with  all  Charnwood 

appliances and can be placed safely at a minimum distance of 

75mm from rear of appliance to face of panel. This includes 
Charnwood appliances above 7kW.

B

Heat shield must extend a minimum of 150mm each side of 
the appliance.

C

Minimum  of  425mm  distance  from  start  of  chimney  to 
ceiling.

D

Minimum of 300mm distance from start of chimney to top 
of  heat shield.

E

Minimum air gap of 25mm from hearth.

F

Minimum of 300mm from top of the appliance to the top 
of the heatshield.

G

Distance from uninsulated flue pipe to wall: 1.5 X 
diameter of the flue pipe.

Heat Shield Installation

rev. 9. 04/21

Stud wall partition

Wall Bracket

C

A

B

E

F

G

VITREOUS ENAMEL

WALL MOUNTED HEAT SHIELD

D