INSTALLATION
1. Screw wall brackets to the wall. See relevant drawing for setting
out dimensions on the reverse page. These are given to the outside
edge of the bracket.
2. Ensure the brackets are level and in line with each other, use slots
for adjustment.
3. Holding the heat shield at the edges lift and drop onto the wall
brackets. Ensure that the panel is the correct way up with the
bottom of the panel having a greater gap.
4. Check the heat shield is seated correctly onto the wall brackets.
CLEANING AND HANDLING
Enamel surfaces must be treated as glass, with care and attention.
To clean enamel surfaces simply wipe over with a dry cloth or soft
brush. Abrasive pads and scouring cleaners must not be used as these
will damage the finish. Care should be taken not to knock the enamel
with hard objects as it will chip.
SAFE DISTANCES
A
Minimum distance of 95mm from rear of appliance to face
of panel for appliances up to 7kW in accordance with
HETAS guidelines.
Charnwood Stoves
Vlaze heatshields have been fully tested with all Charnwood
appliances and can be placed safely at a minimum distance of
75mm from rear of appliance to face of panel. This includes
Charnwood appliances above 7kW.
B
Heat shield must extend a minimum of 150mm each side of
the appliance.
C
Minimum of 425mm distance from start of chimney to
ceiling.
D
Minimum of 300mm distance from start of chimney to top
of heat shield.
E
Minimum air gap of 25mm from hearth.
F
Minimum of 300mm from top of the appliance to the top
of the heatshield.
G
Distance from uninsulated flue pipe to wall: 1.5 X
diameter of the flue pipe.
Heat Shield Installation
rev. 9. 04/21
Stud wall partition
Wall Bracket
C
A
B
E
F
G
VITREOUS ENAMEL
WALL MOUNTED HEAT SHIELD
D