DE 

AXIAL FAN

operating manual

100 PRIM

www.vlano.de

Содержание 100 PRIM

Страница 1: ...DE AXIAL FAN operating manual 100 PRIM www vlano de ...

Страница 2: ...very 6 Brief description 6 Operating rules 6 Designation key 7 Assembly 7 Variants of the fan 8th Operation setting of the fan 8th Maintenance instructions 11 Storage and transport regulations 11 Manufacturer s guarantee 12 2 ...

Страница 3: ...erating instructions is believed to be correct at the time this document was written In order to implement current technical developments the company reserves the right to make changes to the design technical properties and scope of delivery of the device at any time No part of this publication may be reproduced transmitted stored in an information search system or translated into any other langua...

Страница 4: ...e via a circuit breaker QF which is integrated in the stationary line The contact distance must be at least 3 mm at all poles Before installing the device check it for visible defects on the impeller housing and grille Furthermore it must be ensured that there are no foreign bodies in the housing that could damage the impeller blades During assembly make sure that the housing is not deformed Defor...

Страница 5: ... and outlet openings in order to ensure an optimal air flow Please do not sit on the device or leave any objects on it This device may only be used by children from the age of 8 and persons with limited physical mental or sensory abilities or without sufficient experience and knowledge if they have been supervised or have been instructed in the safe use of the device and have understood the result...

Страница 6: ...n flap to prevent air backflow in standby mode OPERATING INSTRUCTIONS The fan is designed for connection to a single phase AC network with a voltage of 220 240 V 50 60 Hz or 12 V 50 Hz depending on the model and is intended for continuous operation without being disconnected from the mains The direction of airflow in the system is indicated by an arrow on the fan housing Degree of protection again...

Страница 7: ... and ensure that the power is switched off Fig 3 Step 2 Route the power cable to the ventilation opening Fig 4 Step 3 Remove the cover from the fan Then remove the cover from the printed circuit board Fig 5 Step 4 Mark and drill the mounting holes and mount the fan Fig 6 8 Step 5 Connect the fan to the power supply in accordance with the connection diagram Fig 12 Step 6 Put the protective cover Fi...

Страница 8: ...ing modes that are set using the DIP switch 100 PRIM V TH the fan is equipped with a humidity sensor and overrun switch The fan works in one of the four operating modes that are set using the DIP switch VT Models are equipped with a cord switch OPERATIONAL SETTING OF THE FAN THE BOARD OF THE TIMER IS POWERED THE FAN BEFORE EVERYONE DISCONNECT SETTING WORK FROM THE POWER SUPPLY The fan is set to op...

Страница 9: ...RIM V TH 100 PRIM V TP functionality When the sensor or switch is triggered the fan runs at a lower speed Speed When the sensor or switch is triggered the fan runs at a high speed The fan is running permanently at low speed At If the sensor or switch is triggered the fan runs at high speed The fan is switched off When triggered switch the fan runs at low speed At If the sensor is triggered the swi...

Страница 10: ...DE Overrun switch The timer is switched off The delay for 5 minutes delay 15 minutes delay 30 minutes delay 100 PRIM V ТР is 30 Seconds Humidity set point 60 70 80 90 10 ...

Страница 11: ... original packaging in a ventilated room at a temperature of 5 C to 40 C and a relative humidity of max 70 Vapors and foreign substances in the air which can cause corrosion and damage connection seals are not permitted Use lifting gear during cargo handling work to prevent possible damage The transport requirements for this type of cargo must be met The transport with vehicles of any kind must be...

Страница 12: ...ation of the device in order to ensure that the device is used as intended within the warranty period Defects are remedied by replacing or repairing the defective parts or units of the device The warranty service does not include regular technical maintenance Assembly disassembly of the device Set up the device For warranty repairs the consumer must present the device the operating instructions wi...

Страница 13: ... authorized by the manufacturer The device s warranty period has expired Violation of applicable regulations for the transport of the device by the consumer Violation of the regulations on the storage of the device by the consumer Unlawful acts by third parties in relation to the device Failure of the device as a result of force majeure fire flood earthquake war military action of any kind blockad...

Страница 14: ...DE 108 158 136 81 ø99 1 2 14th ...

Страница 15: ...DE LN A QF OUT 3rd 4th 5 6th 7th 8th A OUT 9 10 11 15th ...

Страница 16: ...DE QF S LT L N 1 2 3 L N 12th 13 LN A QF OUT 14th 15th A OUT 16 17th 16 ...

Страница 17: ...DE 17th ...

Страница 18: ...DE 18th ...

Страница 19: ...DE Certification mark Sold by Name and stamp of the dealer manufacturing date Purchase date 19th ...

Страница 20: ...Acceptance report V T 100 PRIM DC TP TH The fan is recognized as operational VLN162DE 03 ...