background image

 

22 

|

 

EN

EN | 

23

For the optimum and trouble-free 

operation of the water dispenser, 

please make sure to carry out the 

works described in the next section 

according to the schedule illustrated 

below.

Maintenance works to be carried out by the operator. Do not slide or push 

the system to move it. When moving it must be lifted to avoid damaging the 

sealing lip on the bottom.”

Maintenance works to be carried out by the manufacturer or a qualified 

person

Schedule

MAINTENANCE

Interval

Component

Task

Daily

Drip tray/ 

Waste water container

Empty
Clean

Housing and display

Clean

Outlet tap

Clean

Twice a year

Cooling fins

Clean

Whenever necessary

CO

2  

bottle

Check fill level
Replace

Task

Interval

Water filter replacement

Twice a year

Shut-off and angle valve check
Sanitizing

Twice a year or after a standstill period of 

longer than 4 weeks

Safety check

Every 2 years

Backflow preventer check

Every 5 years

If increased wear is identified during 

routine checks, the required intervals 

should be shortened in accordance 

with the actual signs of wear.

Contact customer service with any 

questions regarding maintenance work 

and intervals (see rear page).

SETTINGS

Portion Settings

It is possible to preset two different portion sizes for 

each water type. 

To enter portion setting mode: 

1. 

Enter the menu.

2. 

Select ‘Portion settings’

3. 

Select portion setting size A or B. 

The system will guide through the next steps. 

To set a portion size:

4. 

Set a suitable vessel under the outlet tap.

5. 

Press the desired water type button.

6. 

Stop pressing when having dispensed the desired 

amount. Make sure not to overfill the vessel.

7. 

Press the ‘confirm’ button to finish setting mode 

or press ‘reject’ to delete the set portion.

8. 

To add more water, press the water icon again.

The setting has to be done separately for every wa-

ter type.

Note:

 The preset portion may vary depending on 

local water supply flow rate.

The portion setting can be adjusted:

1. Off:

 No portion setting available

2. One time:

 Portion size has to be selected for 

every dispense

3. Repetitive: 

Portion size selected last time stays 

activated

Temperature setting

The water temperature 

can be preset to three 

different levels:

   Coldest

   Colder

   Cold

Set water temperature:

1. 

Enter the menu

2. 

Select menu ‘Set 

temperature’

3. 

Select desired tem-

perature. The setting 

will be saved auto-

matically. 

The temperature of the 

set water temperature 

may vary depending on 

local water supply and 

environment tempera-

ture.

Only for operator or service technician

 

IMPORTANT

 

 

It is recommended not to exceed 0.25 gal  

    per portion size. The setup is done at 

 

  operator’s own risk.

Содержание Top 85

Страница 1: ...VIVREAU TOP SERIES EN Operating manual...

Страница 2: ...hygiene is of the utmost importance and consists of three key elements 1 The inlet water filter includes pre fil ter activated carbon and membrane technologies The filter reliably retains tested bact...

Страница 3: ...nt keep any kind of open fire sources well away and ventilate Important safety instructions Please read these safety instructions carefully before using the appliance Keep this manual in a convenient...

Страница 4: ...up puddles of water using SAFETY INSTRUCTIONS the room thoroughly Turn off the appliance immediately Do not pull the plug out of the elec trical outlet as this can become a source of ignition Operate...

Страница 5: ...ocal and regional require ments for the installation of devices connected to the public water supply SAFETY INSTRUCTIONS a cloth immediately Check the drip tray regularly and empty it if necessary Dan...

Страница 6: ...al retailer Endangerment of the environ ment from improper handling of environmentally hazardous substances The improper handling of en vironmentally hazardous sub stances particularly improper dispos...

Страница 7: ...and inquire about suitable measures to be taken The following environmentally hazardous substances are used R290 Refrigerants are ecolog ically friendly but a flammable product They could contain pois...

Страница 8: ...ater dispenser may not be installed near direct or indirect heat sources Hoses and cables must not come into contact with heat sources The CO2 bottle must be placed as far as possible from any heat so...

Страница 9: ...stop automatically when the preset quantity has been reached By pressing any water type button or by pressing stop button on display dispensing will stop imme diately 1 1 2 2 USING THE DEVICE The inst...

Страница 10: ...n the units metrical C liter and em pirical F gal The unit will be saved automatically All settings can only be executed by the operator or the service technician To enter the menu swipe downwards wit...

Страница 11: ...umption in gal l Filter capacity cold in gal l Last cleaning mode Detailed information about the device Status information Statistics on water consumption Statistics Status Info Menu Device type Devic...

Страница 12: ...set two different portion sizes for each water type To enter portion setting mode 1 Enter the menu 2 Select Portion settings 3 Select portion setting size A or B The system will guide through the next...

Страница 13: ...sinfectant al cohol spray suitable for food beverage contact use WARNING Danger to health from contamination Not following the hy giene guidelines can lead to contamination of the end product and coul...

Страница 14: ...of improper handling the pressure on the CO2 bottle can lead to serious or even fatal injuries Before replacing the CO2 bottle Establish a pressureless state Also discharge residual pressure Always en...

Страница 15: ...er a longer period of inactivity CAUTION After standstill times from 4 days up to 4 weeks flush the water dispenser with 2 5 gal of still water and 5 gal of sparkling water After a period of more than...

Страница 16: ...see rear page Sparkling icons are dimmed CO2 bottle is empty Change the CO2 bottle see page 22 Standby Mode is active Touch the icons to wake up the system Others Problem Cause Remedy Water is warm I...

Страница 17: ...nnect the water dispenser from the power supply 1 Disconnect the water dispenser from the power supply 2 Shut off the water supply and collect the leaked water Switch off the water dispenser 2 Shut of...

Страница 18: ...antling Errors in dismantling can lead to life threatening situations or sub stantial property and environmental damage This leads to risks among other things from electrical current carbon dioxide or...

Страница 19: ...1040546 01 2021 12 Vivreau USA 300 Roundhill Drive Unit 2 Rockaway NJ 07866 USA Telephone 1 877 999 1044 E Mail servicena vivreau com www vivreauwater com Local Distributor Dealer stamp...

Отзывы: