13
English
Description
Color
Gauge
IR status DO-
Orange
(26AWG)
IR status DO+
Brown
(26AWG)
LED ON/OFF mode DO-
Black
(26AWG)
LED ON/OFF mode DO+
Red
(26AWG)
Input(V-): 24V AC/DC or 12V DC
Orange
(20AWG)
Input(V+): 24V AC/DC or 12V DC
Brown
(20AWG)
Output(V-): Volts same as input
Black
(20AWG)
Output(V+): Volts same as input
Red
(20AWG)
Listed below is the color scheme for wires coming fom the IR light units.
14.
Prepare two power lines as the 24V inputs for the camera. Connect the input lines
from the enclosure's terminal to that on the camera. Also connect the DO- (black) and the
DO+ (red) lines from the IR unit to the camera's DI pins on the terminal connector. You
only need to connect one pair of day/night mode DO wires to the camera (the other unit
will automatically turn on when light level reaches the preset threshold).
DO+
DO-
DI1+
DI2+
DI3+
DI-
RS485-
RS485+
AC/DC pwr
AC/DC pwr
The day/night mode DO connection enables the synchronization of IR light and the
automated day/night switching mechanism on the camera.