NOTES

• 

Self-protection function:

 The unit will enter a protective mode should the system operate 

continuously in excess of 2 minutes with “HOT” on the controller display.  The system will 
return to normal operation after approximately 18 minutes.

• 

Do NOT remove or reconnect power to reset the unit when in a protective or “HOT” state, as 
this may damage the electronics.

TROUBLESHOOTING

Error Code Description/Resolution

HOT

Heat Warning: Allow desk to rest for 18 minutes.

E10

Motor connection fault:  Disconnect desk power, disconnect the motor, reconnect the

motor, then reconnect power.

E20

Desk overload:  Unplug desk for 10 seconds then reconnect to power.

E02

Obstacle protection.  Desk will automatically move back 4cm after collision.

E31

Under-voltage (power brown out). Will clear automatically when line power is corrected.

E32

Over-voltage (power surge).  Will clear automatically when line power is corrected.

E60

Legs are at different heights.  Reset the desk to align the legs.

• 

Collision Force Detection (CF): 

Press the up or down buttons until the display shows “CF”, and 

press “M” to select.  Press up or down to select “OFF”, Low (L), Normal (n) or Heavy (H) collision 

force detection.  Hold “M” for 2 seconds to save the setting.

Reset Mode

While the unit is powered on, press the down arrow until the desk moves to the fully lowered position. 

Press and hold the down arrow for 5 seconds or until “rES” is displayed to enter reset mode. The desk 

will move down to the lowest possible height and then move back up slightly. The desk will then return 

to operating mode.

• 

E20 - Desk Overload: 

If overloaded while moving up, error will clear after 3 seconds.  If overloaded 

moving down, unplug desk for 10 seconds then reconnect power.

• 

Circuit Protection:

 If motor or controller becomes disconnected, the desk will cease operation.  

Error will clear after all components are reconnected.

Содержание DESK-V120EW

Страница 1: ...nual Scan the QR code with your mobile device or follow the link for helpful videos and specifications related to this product https vivo us com products desk v120ew SKU DESK V120EW Controller help vivo us com www vivo us com 309 278 5303 ...

Страница 2: ...and Downward Movement Press and hold the up or down arrow until the desk reaches the desired height Memory Mode To store a certain height in the controller s memory first press M The current height will begin flashing on the display Now press 1 2 3 or 4 within six seconds to store the current height in memory Each number can store a different height Once in memory you can recall any of the four he...

Страница 3: ...32 Over voltage power surge Will clear automatically when line power is corrected E60 Legs are at different heights Reset the desk to align the legs Collision Force Detection CF Press the up or down buttons until the display shows CF and press M to select Press up or down to select OFF Low L Normal n or Heavy H collision force detection Hold M for 2 seconds to save the setting Reset Mode While the...

Страница 4: ...ce parts to ensure you have a fully functioning product FOR MORE VIVO PRODUCTS CHECK OUT OUR WEBSITE AT www vivo us com Love your new VIVO setup and want to share Tag us in your photo vivo_us help vivo us com www vivo us com 309 278 5303 AVG RESPONSE TIME within office hrs 1HR 8M 23 within 15m 38 within 30m 61 within 1hr 83 within 2hr 92 within 3hr AVG RESOLUTION TIME within office hrs 5M 4S AVG R...

Отзывы: