Checking the identification number of the projector and remote control
The identification number of the projector and remote control can be checked by SERVICE menu as following figure,
“X” represents that the function is not enabled; the number 26 is the current identification number of the remote con-
trol.
Scroll
MENU = Back
Item Adjust
Model
Serial Number
Software Version 1
Software Version 2
Control / Remote ID
Active Source
Signal Format
H/V Refresh Rate
Pixel Clock
Light Time
Constant Brightness (CBC)
Thermal Status
Factory Reset
DU8195Z
C847XXXXX01558
ME03-SE01-FE06t2
LE04-2-RE01-3140
26 / 26
HDMI2
No source
NA / NA
NA
00005 HRS
Off
ALIGNMENT
CONTROL
INPUT
SERVICE
PICTURE
Note
•
If Projector ID Control is set to Off, projector can receive any control signal from the remote control even ID
number is set into the remote control.
•
When the terminal of the remote control cable is inserted to the wired control terminal of the projector, the
projector will automatically switch to the wired control mode and cannot be controlled through the IR signal of
the remote control. Disconnect the wired control terminal on the projector if you want to control through the IR
signal of the remote control.
•
If the wired remote control cable or the external IR transmitter is inserted to the incorrect port, such as Trigger,
the remote control or the IR transmitter may be damaged. Make sure whether the port is correct