5.4.1 - Clean the screen

  

To clean Vimaty touch panel, without generating actions of the application, you can deactivate 

the touch faceplate. For this you can click on the corresponding button. The message: « you can 
clean the screen » appears. After cleaning you can unlock the touch faceplate by pressing one  of 
the five other push buttons. For the GLS version you have to press the screen during 4 seconds.

5.4.2 - Calibration

  

To calibrate  the screen,  touch first one corner  and then  the  second,  as  explained on the 

screen.

5.5 - « Buzzer » button

When  you  touch  the   button,  the   Vimaty  switch   automatically between  « buzzer   ON »  and 

« buzzer OFF » mode.

17/33

Содержание VIMATY 70EIB

Страница 1: ...A T Y 7 0 S V I M A T Y 7 0 E I B V I M A T Y 7 0 S W A L L V I M A T Y 7 0 E I B W A L L V I M A T Y 7 0 G L S V I M A T Y 7 0 E I B G L S D e s k t o p s e r i e s U ser M an u al W a l l s e r i e...

Страница 2: ...his manual may be copied or reproduced in any form without prior written consent of VITY Technology Headquarters France VITY Technology is not responsible for operational technical or editorial errors...

Страница 3: ...ce detector 12 4 10 Date and time 12 4 11 MBC Bus RS485 Interface 12 4 12 Infrared interface 12 4 13 RS232 Interface 12 4 14 EIB interface 13 4 15 Calendar action by day of the week and hours 13 5 PRO...

Страница 4: ...F reader of the VIMATY 70GLS 27 6 4 Cabling of a VIMATY 70S 28 6 5 Cabling of a VIMATY 70EIB 29 6 6 Direct cabling with RJ 45 Vity cable non Ethernet 30 6 7 Cabling infrared connecting block 31 7 BRAN...

Страница 5: ...and hours By perpetual calendar Communication with connection interface 1 x RJ 45 Colors Available in 2 versions White or Black silver Video inputs 4 CVBS or 2YC or 1YC 2 CVBS Temperature From 0 C to...

Страница 6: ...of interconnection PC2MATY software PC2MATY licence 1 3 2 Wall version We have 4 different models for wall version Vimaty 70S WALL infrared output RS 232 in out MBC Bus in out GPI or IR in Vimaty 70E...

Страница 7: ...VIMATY 70 1 3 3 Front of the VIMATY 70 7 33...

Страница 8: ...VIMATY 70 1 3 4 Back of the VIMATY 70 8 33...

Страница 9: ...trix switcher scaler The Vimaty can send commands and receive a feedback RS 232 feedback 2 3 MBC Bus RS485 Vity applications All Vimaty 70 have an RS 485 MBC Bus port to command Vity controllers Monop...

Страница 10: ...stored in a CompactFlash So it is easy to recover the source program to update the application With the application on the CompactFlash it is easier to change the applications by simply changing the...

Страница 11: ...Touch screen The touch screen makes it possible to browse between the various screens of the application Each screen displays control buttons that allow to send commands to the devices connected to th...

Страница 12: ...ersion 4 8 Backlight The screen backlight is adjustable according to the ambient luminosity see setup 4 9 Presence detector The screen backlight is disabled at the end of an adjustable time When a pre...

Страница 13: ...he communication on the standard EIB KNX bus Can accept 240 addresses of 8 Bit each Example KNX device like Switchers take 1 Bit Curtain command take 2 Bits one UP one DOWN Dimmer take 8 Bits Temperat...

Страница 14: ...ARNING allows the learning of the infra red codes used by your application The button DATE HOURS allows the setting the Vimaty time Button SCREEN allows the adjustment the backlighting screen the scre...

Страница 15: ...irection of Vimaty s infrared receiver on the center of the bottom of the Vimaty70 the remote must be between 20 and 50 cm far away of the infrared receiver to allows good infrared learning The buzzer...

Страница 16: ...the modification is immediately effective When you set up time the Vimaty all Vimaty connected to bus RS485 are set up 5 4 Screen button On this page you can update several parameters These values ar...

Страница 17: ...lean the screen appears After cleaning you can unlock the touch faceplate by pressing one of the five other push buttons For the GLS version you have to press the screen during 4 seconds 5 4 2 Calibra...

Страница 18: ...r functions are accessible by this screen 5 6 1 Load parameters from CompactFlash card These values are defined in the file vimaty ini are the backlight level The sleep time the state buzzer the Vimat...

Страница 19: ...n of OS is higher than that already installed on Vimaty The update can be forced if the button at right hand side is pressed when a CompactFlash is inserted Some OS update integrate BIOS updates For t...

Страница 20: ...tor Connecting block 2 points 0 14mm with 0 5mm Gauge 28 20 Connection for a standard dry contact input which acts on the operation of your application The connection for an infra red input which acts...

Страница 21: ...certain points are connected to the common mass of the device Points located 0 on connectors Bus 485 MBC Bus Point located 0 on connectors Bus 232 Point located on the connector In LOG Point located...

Страница 22: ...l version 6 2 1 Wiring of the connecting card The case of embedding has a interconnection card inside The wiring has the same definition that the interface connection see below VIMATY 70S WALL VIMATY...

Страница 23: ...e wall according to the drawing 2 Insert the case to be embedded 3 Use the grip of fixing to block the case 4 Connect the electric cables 5 Fix the Vimaty 70Wall using the 4 provided M4 screws 6 Snap...

Страница 24: ...VIMATY 70 6 2 3 Wall cut out of Vimaty 70WALL version 24 33...

Страница 25: ...VIMATY 70 6 3 GLS version 6 3 1 Wiring of the connecting card 25 33 VIMATY 70S GLS VIMATY 70EIB GLS...

Страница 26: ...VIMATY 70 6 3 2 Wall cut out of Vimaty 70GLS 26 33 Depth 52 mm 2 05...

Страница 27: ...VIMATY 70 6 3 3 How to access to the CF reader of the VIMATY 70GLS 27 33...

Страница 28: ...VIMATY 70 6 4 Cabling of a VIMATY 70S It is the same cabling system for Vimaty 70S WALL and GLS with the integrated interconnection interface 28 33...

Страница 29: ...VIMATY 70 6 5 Cabling of a VIMATY 70EIB It is the same cabling system for Vimaty 70EIB WALL and GLS with the integrated interconnection interface 29 33...

Страница 30: ...t If you use VIMATY 70S you don t need to use interconnection interface You can directly connect the devices with the RJ 45Vity cable delivered with the Vimaty Fot the Vimaty 70EIB you have to use the...

Страница 31: ...in order to drive devices by infrared it is recommended to use infrared connecting block with infrared emitters We propose in option these products VRPT 104 1 infrared connecting blocks with 4 infrare...

Страница 32: ...us Control can control more systems 3M ABB Adtec Akg AllenHeath Analogway Ask Autopatch Barco Behringer Biamp Canon Clipsal CommTec DIS Epson Extron Faroudja Fostex Gyra Hager Imerge Jung JVC Kenwwod...

Страница 33: ...en VITY disclaims and excludes all other warranties whether express implied or statutory 4 Buyer s Exclusive Remedies for Any Nonconformity If a VITY product fails to conform to the warranties in Sect...

Отзывы: