![Vitronics Soltec MR1040A Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/vitronics-soltec/mr1040a/mr1040a_installation-manual_1037583018.webp)
I
NSTALLATION
10
C
HAPTER
1
1.8
I
NSTALLATION
REQUIREMENTS
D
ESCRIPTION
U
NITS
MR 620
MR 710
MR 730
MR 820
MR 840
MR 930
MR 1040
MR1130
Input Voltage
V
3 x 400 (Supply tol10%, -10%)
Frequency
Hz
50/60
Start-Up power
kVA
52
52
54
54
55
56
56
Slow Start-Up power
kVA
44
44
44
44
44
44
44
Power required at setpoint
(depending on configuration, load and
setpoints)
kVA
8
8
9
9
10
11
11
Weight machine Air (maximum)
kg/lb
2
300
/
50
71
2
300
/
50
71
2
300
/
50
71
2
300
/
50
71
2
500
/
55
22
2
500
/
55
22
2
700
/
59
52
2
700
/
59
52
Weight machine Nitrogen (maximum)
kg/lb
2
300
/
50
71
2
300
/
50
71
2
500
/
55
22
2
500
/
55
22
2
700
/
59
52
2
700
/
59
52
2
900
/
63
93
2
900
/
63
93
Carrying capacity per leveling feet
kg/lb
Nitrogen requirements minimum
(only for nitrogen machine)
bar/PSI
4.8 / 70
Nitrogen supply, maximum rate
m
3
/hr /
cfm
50 / 29.43
Nitrogen connection type
½” female NPT
Exhaust volume at single connection
Air Mode - No GRS
m
3
/hr /
cfm
450 / 265 at 300 Pa
Exhaust volume at single connection
Air Mode - GRS - Nitrogen
m
3
/hr /
cfm
200 / 118 at 100 Pa
Exhaust connection
mm /
inch
165 / 6.50
Clearance for operate & maintenance
front,-, infeed,- and outfeedside
mm /
inch
120 /47.25
Clearance for operate & maintenance
backside
mm /
inch
150 / 59.05