05_2018
39
Technical Data
Measuring oil quality
Measurement range 0 to 40 % TPM
Accuracy
±2 % PC
(typical)
Resolution
0.5 % PC
Temperature range +50 to +200 °C
+122 to +392 °F
Optimum range +150 to +180 °C
+302 to +356 °F
Temperature measuring
Accuracy
±1 °C / °F
Resolution
0.1 °C / °F
Response time t90 > 2 min
Instrument
Operating temperature -10 to +50 °C
Instrument housing -50 to + 122 °F
Battery
Lithium button
cell 3 V / 1 Ah,
type CR 2477
Battery life
Typically 3
years
Dimensions
14 x 54 x 22 mm
0,56 x 2,13 x 0,87 in
(L x W x H)
Weight
200g / 0,44 lbs
Housing material ABS
Protection class IP 67