background image

VITEK

VT-TPTZ10HR-2T

2.1 MegaPixel 10x HD-TVI PTZ Camera 

with 6 IR LEDs for up to 165’ IR Range

• 1/3” 2.1 MegaPixel CMOS Sensor
• 30fps live view @ 1920 x 1080p
• True Day/Night by IR Cut Filter
• Built-in 5mm to 50mm Lens offering 10x Optical Zoom
• 6 Integrated IR LEDs with up to 165’ IR Range
• 2DNR Noise Reduction
• 220 Presets programmed with view direction, zoom, BLC, etc
• Max manual speed 480°/sec
• 360°continuous rotation
• 16:9 Video format
• RS485 Communication / COC (Control Over Coax)
• 5.5” double layer metal body construction with IP66 Weather Resistance
• Over 1500’ HD Video Transmission (Depending on cable characteristics and 

integrity)

• Includes Wall Mount Bracket & Power Supply
• 12VDC Operation
• 3 Year Warranty

FEATURES

VT-TPT-CNMT

PTZ Corner Mount 

Adapter Bracket for 

Transcendent HD-TVI & 

IP PTZ Cameras

VVT-TKBD2

Transcendent 3D 

Keyboard Controller for 

Transcendent HD-TVI 

PTZ Cameras

OPTIONAL ACCESSORIES:

VT-TPT-PLMT

PTZ Pole Mount Adapter 

Bracket for Transcendent 

HD-TVI & IP PTZ 

Cameras

VT-TPT-PDM2

PTZ Pedestal Mount for 

Small 5.5” Transcendent 

PTZ Cameras

Содержание VT-TPTZ10HR-2T

Страница 1: ... format RS485 Communication COC Control Over Coax 5 5 double layer metal body construction with IP66 Weather Resistance Over 1500 HD Video Transmission Depending on cable characteristics and integrity Includes Wall Mount Bracket Power Supply 12VDC Operation 3 Year Warranty FEATURES VT TPT CNMT PTZ Corner Mount Adapter Bracket for Transcendent HD TVI IP PTZ Cameras VVT TKBD2 Transcendent 3D Keyboar...

Страница 2: ...L SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating...

Страница 3: ...T 7 2 3 4 Ceiling Mounted Optional Part VT TPT CMT 8 2 4 CONNECTION 10 3 FUNCTION INSTRUCTION 10 3 1 POWER UP ACTION 10 3 2 BASIC FUNCTION 11 3 3 SHORTCUT COMMANDS 11 3 4 SCREEN CHARACTER OPERATION 12 4 OSD MENU 13 4 1 MENU INDEX 13 4 2 SYSTEM INFORMATION 14 4 3 DOME 14 4 3 1 Communication 15 4 3 2 IR Display 15 4 3 3 Guard Tours 16 4 3 4 A B Scan 16 4 3 5 Pan Scan 17 4 3 6 Pattern 17 4 3 7 Park A...

Страница 4: ...ets such as a wall 7 Targets are too dark or faint BLC Back Light Compensation If a bright back light is present the target in the picture may appear dark or as a silhouette BLC enhance the target in the center of the picture the dome uses the center of the pictures to adjust the iris if there is a bright light source outside this area it will wash out to white the camera will adjust the iris so t...

Страница 5: ... according to certain preset order Power Off Memory This feature allows the dome to resume its previous status after power is restored By default setting the dome supports power up memory which improves the reliability and avoids repeated settings of the parameters Park Action If the dome is idle for a set time it will automatically run a preset specific mode pan scan A B scan park action cruise e...

Страница 6: ...all Mounted Wall Mount Bracket Included Fig 1 Installation conditions Wall mounted dome can be used in a hard wall structure whose thickness should be enough to install expansion bolts in indoor and outdoor environment The wall must bear at least 4 times the weight of the dome Install wall hanging bracket Fig 2 b As shown in Fig 3 fix the wall hanging bracket on the wall with wire and cable throug...

Страница 7: ...The wall must bear at least 4 times the weight of the dome Install corner mounted attachment and wall hanging bracket a As shown in Fig5 with the installation holes in the corner mounted attachment as pattern draw locations on the wall with an angle of 90 and drill to install expansion bolt Fig 5 b As shown in Fig6 use M8 screw nut to fix the base of corner mounted on the wall with all cables thro...

Страница 8: ...n be used on a hard pole structure in indoor and outdoor environment whose diameter should match the installation size of stainless hose clamps Factory default is 6 inches stainless hose clamps fit 5 6 polls The pole structure can bear at least 4 times the weight of the dome Install corner mounted attachment and wall hanging bracket a As shown in Fig 9 use the stainless hose clamps to attach the p...

Страница 9: ...nditions Ceiling mounted dome with thick pole can be used in the hard ceiling structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment The ceiling can bear at least 4 times the weight of the dome Install the base of ceiling and boom a As shown in Fig 12 with the installation holes in the base of ceiling as pattern draw punched locations in the ceiling ...

Страница 10: ... the ceiling board Fig 13 Note If the dome is used in the outdoor conditions use the silica gel on the faying surface of the base of hang ceiling and the ceiling board and around the out holes to be sure water proof c As shown in the Fig 14 tighten the boom with electrical wire and cable through it on the base of ceiling and screw up the M4 screw Fig 14 Note If the dome is used in the outdoor cond...

Страница 11: ... 3 1 POWER UP ACTION Power Up Self Testing Pan Tilt Camera Self test Completion Lens action Lens zooms out to the widest angle Pan action Pan rotate in certain direction and stops at zero coordinates Tilt action Tilt rotate in certain direction and stops at zero coordinates From running the action above to power up mode completion power up self testing finishes SYSTEM MFG PROTOCOL AUTO DOME ID COM...

Страница 12: ... special functions 3 3 SHORTCUT COMMANDS Below is list of shortcut commands user can enable the function by shortcut command Call PREST FUNCTION Call PRESET FUNCTION 16 OSD on Call twice 86 BLC on 34 Reset 87 BLC off 35 Wiper on 88 Freeze on 36 Wiper off 89 Freeze off 75 Pattern 1 92 A B scan 76 Pattern 2 94 OSD off 77 Pattern 3 95 OSD on 79 Digital zoom on 96 Guard tour 3 80 Digital zoom off 97 G...

Страница 13: ... OSD Right Enter the option select the item or confirm Left Return to main menu or cancel Angle Display XXX XX pan XXX XX tilt IR Display Display on the lower right corner of the screen Remark 1 Items with mean they have sub menu 2 means the cursor selecting some option 3 When entering the setting page in menu it is useful to call preset 94 to exit the menu directly Such as the sub menu SET in men...

Страница 14: ...Transcendent Series 2 1 MegaPixel 10x HD TVI PTZ Camera 14 4 OSD MENU 4 1 MENU INDEX ...

Страница 15: ...perature of the camera it changes along with the temperature of the camera the data is unchangeable manually VERSION Version will update along with the product upgrading Remark Protocol ID and COMM all can be set in menu COMM 4 3 DOME SYSTEM MFG PROTOCOL PELCO D P DOME ID 001 COMM 2400 N 8 1 TEMPERATURE 41 8 VERSION V863R15122109 EXIT MAIN MENU SYSTEM DOME CAMERA DISPLAY LANGUAGE TIMING TASK ALARM...

Страница 16: ...r saving the dome will reboot Communication settings take effect 4 3 2 IR Display WORKING MODE Working mode has auto black white color selectable Default is auto TESTING TIME On IR auto working mode and the programmed time the IR will execute programmed action accordingly e g Switch from day to night or from night to day The detection time is from 2s to 15s selectable OUTPUT POWER Output power has...

Страница 17: ... 01 10 4 3 3 Guard Tours GUARD TOUR Total 8 guard tours selectable SETTING Each guard tour includes max 16 presets The number of the preset is from 0 64 but 0 is not valid Dwell time is 1 to 60s selectable Speed is 1 to 64 selectable INIT After initial preset point dwell time and speed will resume to default setting RUNNING Running the present guard tour DELETE Delete the guard tour set After dele...

Страница 18: ...be deleted So it is convenient for user to select the preset point needing to be scanned Speed and dwell time will reset as default setting 4 3 5 Pan Scan PAN SCAN SPEED Pan scan speed is 1 to 64 selectable INIT Reset the scan speed and tilt degree as default setting RUNNING Running the scan speed and tilt degree set 4 3 6 Pattern 4 3 7 Park Action 4 3 7 1 4 3 7 2 PAN SCAN PAN SCAN SPEED 20 INIT R...

Страница 19: ...onal 4 3 8 1 4 3 8 2 4 3 8 3 MASK NO Mask No depends on the number of the module supported MASK Mask has on and off selectable SETTING Set the specific parameter of present mask NO And call preset 1 to save the settings Direction operation Modify the coordinate of dome Zoom operation Modify the size of scenery Iris operation Modify the size of privacy zone Remark The mask size is better than doubl...

Страница 20: ... 5 times adjustable 4 4 CAMERA CAM Display the information of module supported by this dome ZOOM SPEED Zoom speed is quick and slow selectable DIGITAL ZOOM Digital zoom is on off selectable FOCUS Focus is auto and manual selectable IRIS Iris is auto and manual selectable BLC BLC is ON and OFF selectable FREEZE Video freeze is ON and OFF selectable Remark Only if those functions are available on th...

Страница 21: ...e it COMM At the top left corner of screen it displays the dome communication information User can enable or disable it TIME Displays the current time on screen 4 6 LANGUAGE LANGUAGE Language can be set as English Espanola French Portuguese Polish Deutsch Italian Default language is English 4 7 TIMING TASK LANGUAGE LANGUAGE ENGLISH EXIT TIMING TASK TIME SETTING TIMING TASK EXIT TIMING SETTING TIME...

Страница 22: ...dome 5 AUTO TEMPERATURE CONTROL This product has built in fan and heater which accordingly cool or heat through temperature sensitive circuit inside the dome RESET DOME RESTART SYS DATA CAM DATA PRESET OK DOME RESTART CONFIRM SAVE DATA DOME RESTART OK SYS DATA CONFIRM FACTORY DEFAULT OK CAM DATA CONFIRM FACTORY DEFAULT OK ...

Страница 23: ...Transcendent Series 2 1 MegaPixel 10x HD TVI PTZ Camera 23 ...

Страница 24: ...Transcendent Series 2 1 MegaPixel 10x HD TVI PTZ Camera 24 ...

Страница 25: ...Transcendent Series 2 1 MegaPixel 10x HD TVI PTZ Camera 25 ...

Страница 26: ...Sensor 1080P 1920x1080 HD TVI 6 Integrated High Power IR LEDs 850nm Up to 165 IR Range IR illumination on 1 15 grades selectable 5mm to 50mm Lens offering 10x Optical Zoom H 47 W 5 3 T V 35 6 W 3 96 T Color 0 1Lux B W 0 01Lux IR Off 0 Lux IR On True Day Night by IR Cut Filter 2D DNR 360 continuous rotation 0 93 auto flip 180 0 02 480 S 0 02 160 S 220 1 64 grades available 1 64 grades setting avail...

Страница 27: ...Alarm inputs 1 Alarm Output Pentaplex Live Display Record Playback Backup Remote Access 1 Internal SATA2 SATA3 HDD Slot supporting up to 6TB VT TTAR410 VT TTAR810 2 Internal SATA2 SATA3 HDD Slots supporting up to 12TB VT TTAR1620 Applications for iOS Android Remote Viewing over the Internet via Web Browser or LAN Mac OS Client CMS Central Management Software Included Supports both Dynamic and Stat...

Страница 28: ...ce replacement for a defective product however all related costs including but not limited to shipping and or delivery charges will be the responsibility of the customer If upon return inspection a product is determined to be in good working order or shows evidence of misuse the customer will be responsible for full payment of the original product purchased as well as the replacement product Beyon...

Отзывы: