vitapur VPS1140 Скачать руководство пользователя страница 1

                                                                                                                                                 

VITAPUR VPS1140

1. Safety InStructIonS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2. product overvIew . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

   

2.1 

water

 

quality

 

parameters

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4

   

2.2 

about

 

your

 

system

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4

 

3. InStallatIon InStructIonS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5
 

 

3.1 

accessibility

orientation

 & 

fittings

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5

 

 

3.2 

optional

 

bypass

 

line

 

and

 

drain

 

valve

 

installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5

 

 

3.3 

in

-

house

 

water

 

distribution

 

system

 

disinfection

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   6

4. operatInG InStructIonS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7

   

4.1

 

initial

 

start

-

up

 

procedure

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7

 

 

4.2 

accredited

 

service

 

technician

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7

5. ServIce and MaIntenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7
 

 

5.1 

lamp

 

installation

 

and

 

replacement

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   8

 

 

5.2 

cleaning

 

the

 

quartz

 

sleeve

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   8

 

 

5.3 

replacement

 

of

 

filter

 

cartridges

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

 

 

5.4 

seasonal

 

use

 

maintenance

 

requirements

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

 

 

5.5 

replacement

 

components

 

ordering

 

information

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   10

6. trouBleSHootInG GuIde. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   10

7. Manufacturer’S lIMIted warranty

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   

Insert

1

Whole Home

Ultraviolet (UV) Water 

Treatment System

Maison entière

Système de filtration 

d'eau ultraviolet (UV)

 

Sistema ultravioleta (UV)

 

de tratamiento de agua

para todo el hogar

Use & Care Guide
Guide d’utilisation 

et d’entretien
Manual d uso 

y cuidado

VPS1140

REV01

save These InsTrucTIons

conserver ces InsTrucTIon

guarde esTas InsTruccIones

Содержание VPS1140

Страница 1: ...E 7 5 1 lamp installation and replacement 8 5 2 cleaning the quartz sleeve 8 5 3 replacement of filter cartridges 9 5 4 seasonal use maintenance requirements 9 5 5 replacement components ordering info...

Страница 2: ...ng Never start the VPS1140 system e g after the initial installation before confirming that the exterior is dry and that there are no visible leaks To prevent damage to the unit always install the VPS...

Страница 3: ...uality Replacement service schedules referenced above should be a maximum and more frequent service cartridge replacement may be required dependant upon your local water quality The VPS1140 is intende...

Страница 4: ...indicator In the event of a failure of the UV lamp the red LED light will flash and a loud beeping will be audible from the electronic ballast of the unit Please note that if these conditions occur a...

Страница 5: ...tz Sleeve use a lint free cloth with alcohol or non abrasive scale remover 9 8 5 1 Lamp Installation and Replacement WARNING The lamp heats up after continuous use and can burn your skin if touched Al...

Страница 6: ...are correctly seated in the housing and the housings are seating properly Testing should be conducted to determine cause of bad taste Additional pre treatment may be required 6 Troubleshooting Guide 1...

Страница 7: ...e de l eau varient normalement entre 41 F 5 C et 100 F 37 7 C DANGER La lampe de cet appareil met des rayons ultraviolets qui peuvent causer des dommages permanents la peau et aux yeux Ne regardez jam...

Страница 8: ...non trait e comme source d approvisionnement elle doit tre d clar e potable par un organisme de sant comp tent de la r gion de la province ou de l tat Si les r sultats des analyses indiquent que 1 le...

Страница 9: ...rifiez si le syst me pr sente des fuites Remarque Vous devez absolument vous assurer que votre syst me d alimentation en eau ne contient plus de chlore avant de l utiliser nouveau FAITES PREUVE D UNE...

Страница 10: ...it r install dans le syst me Prenez soin d emp cher que tout liquide nettoyant n entre en contact avec la surface int rieure du manchon de quartz Instructions pour enlever et r installer le manchon de...

Страница 11: ...onne mais non les lampes UV Les lampes ne sont pas install es correctement V rifier si les lampes sont install es correctement ou si elles sont bien en place Eau laiteuse L eau renferme de petites bul...

Страница 12: ...a l mpara del sistema emite una luz ultravioleta que puede causar da os permanentes en lo ojos y la piel Nunca mire hacia las l mparas cuando la unidad est funcionando Nunca intente usar su sistema VP...

Страница 13: ...es debe de ser confirmada por su agencia de salud local departamental o estatal de su jurisdicci n Si los resultados de las pruebas indican que 1 alguno de los niveles contaminantes antes mencionados...

Страница 14: ...edimento y bloque de carb n en sus carcasas y adj ntelos de nuevo al sistema Aseg rese de que las carcasas est n correctamente colocadas con respecto a las cabezas de los filtros 8 Lentamente abra las...

Страница 15: ...la soluci n limpiadora deber n de ser completamente eliminados antes de reinstalar la cubierta en el sistema Tenga cuidado de que ning n liquido limpiador entre en contacto con al superficie interior...

Страница 16: ...ultravioleta cuando el sistema se encuentra estancado El disyuntor de escape de corriente a tierra GFCI se activ Reestabl zcalo siguiendo las instrucciones dadas por el fabricante Revise el enchufe co...

Отзывы: