To Install a Tip
1. Insert nozzle into tip.
2. Lightly press down until a
“click” is heard. This
indicates the tip is securely
sealed onto the nozzle.
M
Quick Reference Guide for
Mechanical Volume-Adjust Pipettes
Refer to Operator’s Guide at www.vistalab.com for complete instructions.
To Aspirate & Dispense
1. Depress plunger to the first stop.
2. Place tip in sample and release
plunger, wait one second, then
remove tip from sample.
3. Depress plunger to first stop,
wait one second and then fully
depress plunger.
To Eject a Tip
1. Point tip into a waste container.
2. Press the tip eject button.
The ejector sleeve is activated,
effortlessly discarding the tip.
To Pick Up Ovation
1. Allow body to fill palm
2. Rotate adjustable hook
to rest comfortably on
your forefinger
Ejector Sleeve
Nozzle
Volume Display
Body
Tip Eject Button
Adjustable
Hook
Plunger
Volume Label
Built-in Cap Opener
To Set Volume
1. Rotate the plunger to display the desired volume.
(clockwise to decrease, counter clockwise to increase).
Do not rotate beyond the pipette’s volume limits!
This will damage the pipette and void its warranty.
The Ovation M pipette is a variable volume, air displacement,
2 stroke pipette intended to aspirate and dispense
precise fluid volumes.
Example Catalog number
4060-1002
VistaLab Technologies, Inc.
2 Geneva Road
Brewster, NY 10509 USA
(888) 652-6520 or (914) 244-6226
L070-0002-001 Rev.
C
Calibration Ring
Tips and Accessories
VistaRak
™
VistaStak
™
Stacked Rack
0.2-2µL
Ovation M mechanical volume-adjust models:
1.0-10µL
10-100µL
2.0-20µL 20-200µL
100-1000µL
T I P S I Z E : M I C R O S M A L L L A R G E
Notes: 1. Not for use with Ovation M .02-2µL. 2. Ejector sleeve not available for Ovation M .02-2µL.
N
O
N
-
S
T
E
R
I
L
E
S
T
E
R
I
L
E
F
I
L
T
E
R
E
D
VistaRak
192 tips/rack, 5 racks
4060-1002 4060-2004 4060-3004
VistaRak, Low Retention
192 tips/rack, 5 racks
4070-1002LR 4070-2004LR 4070-3004LR
VistaStak, 192 tips/layer, 5 layers (small size)
or 3 layers (micro and large size)
4060-9024 4060-9025 4060-9026
Stacked Rack, 200 tips/layer,
5 layers (small size) or 3 layers (large size)
9025
9026
Stacked Rack, Trace Metal Certified, 200 tips/layer
5 layers (small size) or 3 layers (large size)
9022
9023
VistaBulk
™
, 1000 tips/bag, or
250 tips/bag (5mL) or 100 tips/bag (10mL)
4058-1000 4058-2000 4058-3000
Protectainer
™
Bulk Pack,
1000 tips (small) or 750 tips (large)
4025
4026
Econo-Pak
™
Bulk Pack,
1000 tips
4225
4226
4060-1032 4060-2132 4060-3132
4070-1032LR 4070-2132LR 4070-3132LR
2025
2026
2027
2028
4060-1332
1
4060-2332 4060-3332
4060-1333
†
4070-1332LR
1
4070-2332LR 4070-3332LR
4070-1333LR
†
Nozzle, 5/box (0.2–2µL) or 10/box
9057-1013
†
9057-2010
9057-3017
† for Ovation 0.2-20µL only
9057-1010
Nozzle Replacement Filters, 25/bag
n/a
9057-2009 9057-3009
Type A Nozzle, 5/box
n/a
n/a
9057-1017
Nozzle Extender (except 0.2-2µL)
9057-1012
9057-3012
Ejector Sleeve
9057-1011
2
9057-3011
Calibration Labels, 5/box
9057-4002
Ovation Pipette Stand
9057-4003
Calibration Key
9070-4007
A
C
C
E
S
S
O
R
I
E
S
QRG_OvationM_Rev
C
VistaRak, Sterile,
non-pyrogenic, certified
RNase/DNase
free
, 192 tips/rack, 5 racks
VistaRak, Sterile,
non-pyrogenic,
Low Retention,
certified
RNase/DNase
free,
192 tips/rack, 5 racks
VistaTip
™
Individually Wrapped
Sterile, 200 tips
VistaTip Individually Wrapped, Sterile,
non-pyrogenic
, 200 tips
VistaRak, Filtered, Sterile,
non-pyrogenic,
certified RNase/DNase free,
192 tips/rack, 5 racks
VistaRak, Filtered, Sterile,
non-pyrogenic,
Low Retention, certified RNase/DNase free
192 tips/rack, 5 racks
†
2µL tip for Ovation 0.2-2µL
†
2µL tip for Ovation 0.2-2µL