Declaration of Conformity 

VistaLab Technologies Inc. declares on its own responsibility that the devices 

ali-Q 2 aliquoting pipet controller, Model 2100-0005  
ali-Q 2 LS aliquoting pipet controller, Model 2100-0003 
ali-Q 2 VS aliquoting pipet controller, Model 2100-1005 

comply with: 

Green/Ecodesign Regulations 

Meet CEC, DoE Level VI, Energy Star, ErP Stage 2 

NRCan & GEMS 

 

No Load Power Consumption Less 0.075W 

Standards for EU 

Safety requirements for electrical equipment for measurement, control 

and laboratory use- General Requirements 

EN 61010-1:2010 

Electrical equipment for measurement, control and laboratory use- EMC 

requirements 

EN 61326-1:2013 

Information Technology Equipment Safety General Requirements 

EN60950-1:2006 

A2:2013 

Standards for Canada and USA 

Safety requirements for electrical equipment for measurement, control 

and laboratory use- General Requirements 

CAN/CSA-C22.2 

No. 61010-1 

Safety requirements for electrical equipment for measurement, control 

and laboratory use- General Requirements 

UL 61010-1 

Operation is subject to the following two conditions: (1) this device 

may not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause 

undesired operation. 

Part 15 of the 

FCC Rules Class A 

Copyright ©2020 VistaLab Technologies, Inc. USA. All rights reserved, including graphics and images. 

No part of this publication may be reproduced without prior permission of the copyright owner. 

VistaLab Technologies and the VistaLab Technologies logo are trademarks of VistaLab Technologies, 

Inc. USA. ali-Q is a trademark of VistaLab Technologies, Inc. 

Registered trademarks and protected trademarks are not marked in all cases with

 ®

 or 

 in this 

manual.  

U.S Patents are listed on www.vistalab.com/about/quality-management 

Lit # : L080-0060-001 Rev D 

Содержание 2100-0003

Страница 1: ...ali Q 2 Series Operating Manual...

Страница 2: ...tem 9 Wall Mount 9 Kickstand 9 Technical Specifications 10 Calibration 11 In lab Calibration Protocol 12 Initial PerformanceVerificationWorksheet 12 Troubleshooting 14 Maintenance 15 Cleaning Decontam...

Страница 3: ...8 Use only VistaLab accessories and spare parts See Ordering Information on pg 18 Do not attempt to make any technical alterations Do not dismantle the instrument any further than is described in the...

Страница 4: ...arging port USB C N A 4 Aliquot button Nylon 5 Aspirate button Nylon 6 Dispense button Nylon 7 Battery Lithium ion Lithium Polymer 8 Battery compartment cover PC ABS 9 Nozzle Cover Nylon 10 Nozzle Ins...

Страница 5: ...ional part of a total amount of a solution or suspension verb To divide as a solution into equal parts Aspirate verb to draw by suction Dispense verb to expel liquid Serological Pipet pipet noun dispo...

Страница 6: ...Mode see next page the speed that the ali Q 2 aspirates and dispenses liquid is controlled by the touch sensitive aspirate and dispense buttons The amount of force used to push on the buttons determin...

Страница 7: ...the bottom gray dispense button until bottom of meniscus is at the desired volume graduation ATTENTION Do not fill the serological pipet over the max volume Severe damage can occur if any liquid ente...

Страница 8: ...as you will need Ex If you need to dispense 10 aliquots of 2 mL you will need to aspirate at least 20 mL of liquid 5 Aliquot Carefully position the tip of the full pipet over the first receiving vess...

Страница 9: ...has different sizes and geometries These geometric differences contribute to changes in the physical characteristics of the system ali Q 2 can sense the effect of these differences and will automatica...

Страница 10: ...racy Precision CV 3 0 mL 2 1 0 3 mL 3 3 With any other brand of serological pipet any size Dimensions 7 2 x 7 0 x 2 2 18 3 cm x 17 8 cm x 5 6 cm Weight 350g Volume Capacity Accepts 1 to 100 mL serolog...

Страница 11: ...ends sending ali Q 2 to VistaLab for calibration or performing verification at least once a year or whenever conditions and equipment change In lab Verification Adjustment Users can verify the accurac...

Страница 12: ...e initial current error at 0 5 and 5 0 mL and record the 2 numbers to use in the following calibration procedure Worksheet Determine the current accuracy of your ali Q 2 by taking the average of 4 gra...

Страница 13: ...dispensing too high 1 5 error press the Aspirate button to save the changes If the ali Q 2 is dispensing too low 1 5 error press the Dispense button to save the changes The 2 LEDs will alternate blue...

Страница 14: ...filter properly see pg 4 Replace nozzle insert Send ali Q 2 in for repair service Pipet does not stay in ali Q 2 Nozzle insert worn or damaged Replace nozzle insert NOTE Using Wobble not pipets will...

Страница 15: ...54 nm wavelength from UV sterilization lamps NOTE The effects of the UV exposure will likely cause discoloration over time Autoclaving NEVER AUTOCLAVE ALI Q 2 Only the nozzle cover nozzle insert and m...

Страница 16: ...the power supply pack and insert into wall outlet 2 Attach the wide end of the USB C charging cord to the power supply pack 3 Plug the USB C end of the charging cord into the charging port of the ali...

Страница 17: ...hnical Support to receive Return Authorization Unit will be inspected for defects and repaired replaced as necessary at the sole discretion of VistaLab Customer will be responsible for service charges...

Страница 18: ...terile 5 pack 9020 4006 Replacement Membrane Filter 0 45 m sterile 5 pack 9020 4008 Replacement Silicone Nozzle Insert 2 pack 9020 4010 Replacement Nozzle Cover 1 pack 9020 4011 Replacement Kickstand...

Страница 19: ...of their service life According to the Directive 2002 96 EC of the European parliament and of the Council on Waste Electrical Equipment WEEE of 27 January 2003 electronic equipment requires disposal a...

Страница 20: ...rical equipment for measurement control and laboratory use General Requirements CAN CSA C22 2 No 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General...

Отзывы: