background image

Vista VC200 Series Compact Cameras

Installation Instructions

PRODUCT SAFETY

This  camera  range  is  designed  for  use  in  general  purpose  CCTV  applications  and  has  no  other  purpose.  Only  operate  your

camera between the temperatures of -10

O

C and +50

O

C. Do not operate your camera outside its specified power supply range.

Cameras must only be used in clean, dry, dust-free environments unless housed in suitable protective housings to IP65 or better.

In order to avoid damaging the camera note the following points.
1. Installation and servicing is only to be carried out by suitably qualified and experienced personnel.
2. Only power cameras from a class 2 isolated power supply.
3. Do not touch the image-surface of the sensor.  If the sensor is accidentally touched, only clean it using isopropanol.
4. Do not expose the sensor to direct sunlight as this may impair the performance of the camera.
5. For outdoor use, an appropriate protective housing conforming to IP65 or UL50 or better must be used.

ELECTROMAGNETIC COMPATIBILITY (EMC)

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may

be required to take adequate measures.

This product is intended solely for use in general CCTV applications.
The product must be installed and maintained in accordance with good installation practice to enable the product to function as

intended and to prevent problems. Refer to Norbain SD Limited for installation guidance.

MANUFACTURER’S DECLARATION OF CONFORMANCE

The manufacturer declares that the equipment supplied with this manual is compliant with the essential protection requirements

of the EMC directive 89/336 and the Low Voltage Directive LVD 73/23 EEC. Conforming to the requirements of standards EN 55022

for emissions, IEC801 parts 2, 3 and 4 for immunity and EN 60950 for Electrical Equipment safety.

CONTROLS AND SWITCHES

The diagram below shows the locations and functions of the controls and switches.

Mounting Bolt

Two 1/4” 20 UNC mounting bolts are provided for mounting the camera, one on the the top of the case and one on the bottom of

the case.

Lens Level Adustment

If the camera is used with a direct drive (DD) lens this potentiometer varies the DC reference voltage used to control the lens. The

potentiometer has the effect of increasing or decreasing the lens aperture. This potentiometer should be adjusted to obtain a 1V

pk-pk video output and is therefore the factory setting.

Composite Video

To obtain a 1.0V [pk-pk] composite video signal, connect a video coaxial cable terminated with a 75 Ohm BNC connector to the BNC

socket marked VIDEO OUT.

Supply Terminals

These terminals accept a power supply of 12 VDC ±10%, ripple less than 200mV.

EI on/off

The  Electronic  Iris  (EI)  compensates  for  excessive  light  level  by  automatically  adjusting  the  shutter  speed.  The  electronic  iris

should be 

ON 

when using fixed or manual iris lenses. When using Auto Iris DC lenses, the EI must be 

OFF

. See also Lens Level

Adjustment. The default setting is 

ON

.

ON

1 2

ON

1 2

BLC ON/OFF

EI ON/OFF

COMPOSITE VIDEO

SUPPLY

12V DC

MOUNTING BOLT

LENS LEVEL
ADJUSTMENT

DIRECT DRIVE LENS
CONNECTOR

MOUNTING BOLT

White denotes switch position

(default settings shown).