background image

 

 

 

 

 

 

 
 

Vista QSW16M & QSW24M   

16/24-Port 10/100Mbps PoE+ and 2-Port Gigabit   

PoE Managed Switch

 

 

Web-based PoE Management 

Configuration Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1.0 

 

Содержание QSW16M

Страница 1: ...Vista QSW16M QSW24M 16 24 Port 10 100Mbps PoE and 2 Port Gigabit PoE Managed Switch Web based PoE Management Configuration Guide V1 0...

Страница 2: ...e only No warranties of any kind either express or implied are made in relation to the description information or suggestion or any other contents of the manual The images shown here are indicative on...

Страница 3: ...ents 1 2 2 Software Requirements 1 Set Up Network Connection 1 3 1 Set Static IP for the Management Computer 2 3 2 Confirm the Network Connection by Ping Command 3 3 3 Cancel the Proxy Server 4 Login...

Страница 4: ...t Please follow the instructions below to configure the switch via the Web system Environment Requirements 2 1 Hardware Requirements A Windows PC laptop with an Ethernet network card is required Conne...

Страница 5: ...ndows start button bottom left to open the start menu select control panel Double click the network connection icon then double click the local connection icon The local Area Connection Status window...

Страница 6: ...essential Leave empty unless you have such details for your network 3 2 Confirm the Network Connection via Ping Command Operation Steps as below Step1 Click the Windows Start button bottom left to ent...

Страница 7: ...page Follow the below to confirm Step1 Open your Internet Explorer browser select Tool Internet Option to enter Internet Options window right and click the Connections tab Step2 Click in Internet Opti...

Страница 8: ...You should be prompted for the login ID and password defaults below Items Default value Switch default IP address 192 168 1 200 Subnet mask 255 255 255 0 Administrator s account admin Administrator s...

Страница 9: ...er will be divided to each port as further demand increases 4 Click OK button to save the configuration Total Power Status Function View the real time input and output power of the switch Parameter Co...

Страница 10: ...t IP Address Default value 192 168 1 200 3 Set Subnet Mask Default value 255 255 255 0 4 Set Default Gateway The default gateway the switch linking with Default value 192 168 1 1 5 Click OK button to...

Страница 11: ...meout If users do not perform any operations on the Web system GUI for a long time your account will be logged out and the login page displayed The auto log out interval time is 5 minutes If you need...