![Visonic MR-4000 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/visonic/mr-4000/mr-4000_installation-instructions_1033157001.webp)
DE1141
1
055
Flush Mount PIR Detectors
Installation Instructions
,1752'8&7,21
The MR-4000 (vertical unit) and MR-4000R (horizontal unit) are
flush mounted PIRs for wired installations. They fit into virtually
any standard single-gang electrical box, but may also be installed
directly into the wall without a box or a special installation kit.
Superior engineering gives you these added features:
•
Flush mounting in a standard
electrical box
•
Ideal for pre-wired installations
•
145
ultra-wide angle lens
•
Super RFI protection
•
Virtually zero false alarms
•
Interchangeable lenses
•
12
vertical and horizontal
adjustment
•
Programmable pulse counter
•
Plug-in wiring connector
•
Entirely sealed construction
The MR-4000 provides a variety of
outstanding features including
adjustable pulse counter and RFl
protection up to 1000 MHz, to
ensure the highest level of reliability
and false alarm immunity along with
added flexibility.
User-friendly design includes instal-
lation aids for precise positioning at
the desired height.
Figure 1. Model MR-4000
for Vertical Installation
Max. coverage: 9 m (30 ft) / 90
.
Application: 3 vertical "finger
Maximum coverage:
27 x 3 m (90 x 10 ft)
Application: corridors and
long walls.
Mounting Height:
0.8 to 1.2 m (2.5 to 4 ft)
Maximum coverage:
10 m (30 ft) radius/145
°
Application: provides the
largest and widest room
coverage for general-
purpose applications.
(Standard Lens)
Maximum coverage:
13.5 m (45 ft) radius/90
Application: general use -
high density coverage.
curtains" which may be used as
3 individual traps within the
protected area. The coverage of
each curtain should be walk-
tested-separately.
NOTE! A wide dead zone exists
between the curtains.
Maximum coverage:
15 m (50 ft) radius/90
.
Application: allows pets to
move freely under coverage
pattern, undetected.
Mounting Height:
0.8 to 1.5 m (2.5 to 5 ft)
Beam Splitting: By dual-
element detector that creates
two detection zones for each
segment in the lens array,
doubling the number of detec-
ting beams in the coverage
pattern
.
Figure 2
Lens No. 4, Ultra-Wide
Figure 3
Lens No. 1, Wide-Angle
Figure 4
Lens No. 3, Triple Curtain
Figure 5
Lens No. 5, Pet Alley
Figure 6
Lens No. 2, Long-Range
63(&,),&$7,216
OPTICAL
Standard Lens: Lens No. 4 is the standard pattern supplied with
each MR-4000. It provides 34 beams in 3 detection layers, 145
°
ultra-wide angle, maximum coverage area of 9 m (30 ft) radius.
Interchangeable Lenses (same as used with MR-3000 series):
Lens No. 1 - Wide-Angle 90
, 13.5 m (45 ft) radius.
Lens No. 2 - Long-Range, 27 m x 3 m (90 ft x 10 ft)
Lens No. 3 - Triple curtain, 9 m (30 ft)
Lens No. 5 - Pet Alley, 90
, 15 m (50 ft) radius.
Calibration: 0
°
to -12
°
(vertical);
±
7.5
°
(horizontal)
ELECTRICAL
Voltage: 9 to 16 VDC.
Current Drain: 25 mA.
Relay Output: Normally Closed (fail safe) contacts. 18-ohm
resistor in series with contacts. Rating - 0.1 A resistive /30 VDC.
Alarm Period: 2-3 seconds.
Pulse Counter: Selectable 1 or 3 pulse operation.
Tamper Contacts (optional): N. C., 0.5 A resistive / 30 VDC.
LED: Switchable ON or OFF.
Detector: Dual-element low-noise pyroelectric sensor.
MOUNTING
Flush mounted into virtually any standard single-gang electrical
box or installed directly into the wall (without box).
ENVIRONMENTAL
Operating Temperature: -10
C to 50
C (14
F to 122
F).
Storage Temperature: -20
C to 60
C (-4
F to 140
F).
RFl Protection: No alarm when tested on 21 different
frequencies from 20 to 1000 MHz with 124 Watt radio transmitter
at 3 m (10 ft) distance (equivalent to field strength of 20 V/m).
PHYSICAL
Dimensions: 125 x 85 x 48 mm (5 x 3.3 x 1.9 in.).
Weight: 90 g (3 oz).
Color: Soft white.
MODELS AVAILABLE
MR-4000: Standard model for vertical mounting.
MR-4000R: For horizontal mounting.
ACCESSORIES:
TS-1: Tamper switch module.
MRB-403: Standard single-gang back box.