1. INTRODUCTION
The MCS-710 is an indoor or outdoor fully wireless siren,
designed for installation in areas in which wiring action is difficult
or impossible. There is no need for an external power supply. The
MCS-710 is powered by an internal non-chargeable battery.
The siren communicates with the P, PowerMax Pro or
PowerMax LE. When an identified activation command is received
from the control panel, the siren activates its sounder, activates its
flash lights and acknowledges its activation to the alarm system.
The MCS-710 and the control panel should be located in the
same house.
MCS-710 Features
•
Designed for indoor or outdoor use
The siren has double plastic cover for extra protection against
rain and sun.
•
Distinguishable siren fire and burglar alarms
Fire alarm:
Alternating on/off alarm sound.
Burglary alarm:
Continuous high/low tone sweep.
Note:
The siren is activated for a predefined "Bell Time" (refer to
P
/ PowerMax Pro / PowerMax LE
installer guide, par.
4.4) according to local authorities requirements. After this period,
the siren sound stops.
•
Squawk indications
By using a keyfob, High, mid or low siren squawk (beep)
sounds can be used to indicate arming (1 squawk) and
disarming (2 squawks) of the P / PowerMax Pro /
PowerMax LE (as described in the user's guide section 7).
•
Flash lights
The siren includes 6 flash lights that are activated as follows:
When an identified activation command is received from the
control panel, the siren starts sounding for a predetermined
time (set by the P / PowerMax Pro / PowerMax LE
"4. DEFINE PANEL", "04: BELL TIME" menu). (The siren
sound can be stopped by the disarming the control panel).
After the siren sounding period (if the alarm system is not
disarmed) the siren lights flash once every 1 second (0.1
second ON, 0.9 second OFF) for a period of 20 minutes, or
until the alarm system is disarmed.
•
Triple Tamper protection
3 tamper switches are included; one under the front cover, second
touching the mounting surface and third attached to the closure
screw.
Figure 1 - External View
•
Non-rechargeable 3.6V Lithium battery
When the battery voltage is low, low battery message is sent
to the alarm control system. After the low voltage message
delivery, at least 2 siren alarms will be possible before the
siren will be totally inactive.
•
2-way full supervision
The siren is a fully supervised, 2-way communication device.
It includes a receiver, to receive activation commands from
the alarm system, and a transmitter, to periodically transmit
its status signal to the alarm system.
The transmitted signal strength can be measured during the
installation (refer to P / PowerMax Pro / PowerMax
LE installer guide, paragraph 5.2 – Diagnostic Test).
•
Self-test feature
Upon pressing the MCS-710 self test switch for 3 seconds,
the siren functional check is performed (low level sounds and
flash lights indicate that that siren is serviceable).
MCS-710
Hard wired detector
Smoke detector
Wireless transmitter
Door or window
open/close detector
Motion detector
Remote commander
P /
PowerMax Pro/
PowerMax LE
Figure 2- Integration with the Alarm System
Note:
When the P / PowerMax Pro /
PowerMax LE
is
no longer used, or its power is switched off for a long period, the
siren's internal battery should be removed to preserve battery
life.
2. SPECIFICATIONS
Siren Type:
Piezo, 100dB min. SPL @ 1m, 1.8-3.5 kHz, sweep
frequency 7Hz
Internal Battery:
3.6V non-rechargeable Lithium battery, EEMB
type ER34615M
Battery life expectancy:
3 years (for typical use)
Operating Frequency (MHz):
315, 433.92, 868.95, or other
frequency according to the requirement in the country of use.
Receiver and Transmitter ID Type:
24-bit
Flash Lights Duration:
100ms ON, 900ms OFF
Dimensions (LxWxD):
30 x 19 x 7 cm (11-13/16 x 7-1/2 x 2-3/4 in)
Weight:
982g (34.6 oz.)
Operating Temperature: -
30
°
C to 70
°
C (-22
°
F to 158
°
F)
Compliance with Standards:
EN 50131-1 Grade 2 Class II