1. INTRODUCTION

The MCR-300/UART module is a PowerCode receiver interface module 
designed to communicate with Visonic PowerCode / CodeSecure 
wireless devices. The module includes a super-heterodyne receiver 
module, specifically for digital data transfer on UHF radio channels. Its 
main application is as an RF interface unit used in security systems that 
communicates digital codes and reports. The receiver features serial 
data output at CMOS levels, which may be applied to a decoder or 
directly to a micro-processor unit. 

The Module decodes PowerCode & CodeSecure wireless messages 
and transfers them into a serial bit stream as defined by the receiver 
protocol description. 
The module includes two integral antennas for diversity reception, 
allowing high performance reception, overcoming "in-band" interference. 
Mechanical support and electrical connections to the MCR-300/UART 
are obtained by mounting the module on a 5-pin header seated on the 
host motherboard. The header pins are connected to a panel. 

 

2. SPECIFICATIONS 

Receiver Type:

 Single-channel, UHF super-heterodyne receiver. 

Frequency: 

868.95 MHz 

Bandwidth:

 400

 

kHz

 

@

 

-3dB

 

points 

Data Rate:

 Up to 1 kbps NRZ.

 

Data Output Levels:

 0V (LOW) and 5V (HIGH). 

Baud rate: 

9600 

Parity bit:

 None

 

Data bit: 

Stop bit:

 1

 

UART interface 
2 Integral Antennas diversity reception allowing high performance 
reception, overcoming "in-band" interference. Length

: 80mm

 

Supply Voltage:

 5 VDC ±5%. 

Current Consumption:

 15 mA @ 5 VDC. 

2 MGC-Manual Control Gain: 

  MGC - High "5V" - Sensitivity attenuation 30dB. 

  MGC - High impedance - Normal Sensitivity 

Note: Do not connect MGC to GND 
Operating Temperatures:

 0°C to 49°C (32°F to 120°F). 

Dimensions:

 52.5 x 51 x 12 mm  

Compliance with Standards:

 Complies with EN 301 489-3 V1.2.1 

(2000-08), EN 300 220-1 (1999) and EN 50131-1 Grade 2, Class II 
requirements. 

Note: A sample disc can be obtained on email request. 

GND

RX

TX

5V

MGC

GND

RSSI

DATA

5V

MGC

PIN HEADER

RFR MODULE

GND

GND

ANT

51 mm

80 mm

28 mm

4 mm

 

Figure 1. Top View of PCB and Electrical Connections 

WARNING:  Changes or modifications to this unit not expressly 
approved by the party responsible for compliance could void the 
user's authority to operate the equipment
.

 

 

3. WIRING AND SETTINGS 

5

VDC

RJ-11

RS-232 ADAPTER

to COM-1 or COM-2

PC connector

Display of detectors communication format

(PowerCode/CodeSecure), signal strength,

ID and events data

2-wire cable

PowerCode /

SecureCode

Device

Antenna

PowerCode /

SecureCode

Device

GND

RX

TX

5V

MGC

GND

RSSI

DATA

5V

MGC

PIN HEADER

RFR MODULE

GND

GND

ANT

51 mm

80 mm

28 mm

4 mm

 

Note: Make sure that com ports 1 and 2 of your computer are not being used by another application. 

Figure 2. Functional Diagram

 

 

DE3140U 

Содержание MCR-300/UART

Страница 1: ...GH Baud rate 9600 Parity bit None Data bit 8 Stop bit 1 UART interface 2 Integral Antennas diversity reception allowing high performance reception overcoming in band interference Length 80mm Supply Voltage 5 VDC 5 Current Consumption 15 mA 5 VDC 2 MGC Manual Control Gain MGC High 5V Sensitivity attenuation 30dB MGC High impedance Normal Sensitivity Note Do not connect MGC to GND Operating Temperat...

Страница 2: ...ssage will be sent again The Receiver Module sends a Supervision message using a Control message every minute Any Data message or Control message successfully sent is also considered a supervision message Timer of supervision at the Receiver Module is cleared after every message that is sent An acknowledge message will be sent by the Control Panel to the Receiver Module after every message sent by...

Страница 3: ...n window The open window is a reception of a transmission where the synchronization counter is 1 to 16 higher than the previous counter value received The reception of such a signal will result in an immediate counter update by the control panel program and the appropriate outputs being activated If the transmitter is pressed more than 16 times out of range of the receiver resynchronization needs ...

Страница 4: ...nty of merchantability or fitness for a particular purpose or otherwise In no case shall the Manufacturer be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties whatsoever as aforesaid This warranty shall not be modified varied or extended and the Manufacturer does not authorize any person to act on its behalf in the modification variati...