To send video over IP between two units with a direct Ethernet connection, do the
following:
1.
In the receiving device, set the IP address of the IP block (or leave as default), under
IP Video Setup. The Mask and Gateway are only necessary if the traffic is going to
pass over a network.
2.
In the receiving device, set the IP Port to the required value (or leave as default).
3.
In the sending device, set the Destination IP Address (under ASI to IP) to the value set
in step 1.
4.
In the sending device, set the Destination Port to the value set in step 2.
5.
In the sending device, set the source of the IP block as required (either Demodulator
or ASI Input).
6.
In the receiving device, set the destination of the IP block as required (either Decoder
or ASI output).
On the receiving device, status can be monitored on the IP Video Setup page. The steps
above are similar when using other devices at either end of the link. If a network is being
used, then ensure that all the IP addresses on the network are unique, and that they all
have the same subnet mask.
The receiver can provide various decryption options depending on the license options for
the unit.
First, the required decryption algorithm is selected and the appropriate key is then
entered, either from the front panel or via Link Control software running on a PC.
For the AES keys these must be entered in two (AES128) or four (AES256) 8-byte segments.
The BISS-1, BISS-E and AES+ decryption will only decode an encrypted stream; EBS and AES
will decode non-encrypted (clear) streams and also the appropriately encrypted streams.
This option allows for the use of third party down convertors with the L217x receiver.
The user must first select a down convertor of the Other type in the Demod >
Downconverter menu, then select the required LO frequency and polarity. These can be
set individually for each of the RF inputs. These can then be stored as any one of the Config