Overview

 

The

 

intent

 

of

 

this

 

document

 

is

 

to

 

assist

 

the

 

user

 

with

 

the

 

initial

 

set

 

up

 

of

 

the

 

NewS

tream

 

system

 

as

 

quickly

 

as

 

possible

 

using

 

the

 

default

 

settings.

   

The

 

NewStream

 

ships

 

with

 

three

 

default

 

presets,

 

one

 

for

 

each

 

mode

 

of

 

operation

 

(ENG,

 

CNG,

 

and

 

SNG)

 

which

 

can

 

be

 

used

 

immediately

 

to

 

transmit

 

or

 

stream

 

video

 

/

 

audio

 

according

 

to

 

the

 

licensed

 

features

 

ordered.

 

The

 

NewS

tream

 

system,

 

depending

 

on

 

the

 

mode,

 

utilizes

 

a

 

RF

 

outdoor

 

unit

 

(RFODU)

 

for

 

microwave

 

transmission,

 

a

 

Cellular

 

outdoor

 

unit

 

(CODU)

 

for

 

Cellular

 

transmission,

 

and

 

L

band

 

outputs

 

for

 

Satellite

 

transmission.

  

Quick

 

Start

 

Process

 

(ENG)

  

1.

 

Connect

 

the

 

NewS

tream

 

or

 

a

 

legacy

 

ODU

 

to

 

the

 

IDU

 

(refer

 

to

 

the

 

IDU

 

Rear

 

Panel

 

Connections

 

section

 

of

 

this

 

document

 

for

 

cable

 

connections)

 

and

 

set

 

the

 

ODU

 

switch

 

on

 

rear

 

panel

 

to

 

match

 

the

 

ODU

 

type.

 

 

WARNING

:

  

If the ODU switch is placed in the wrong position or if you change the ODU type without changing the switch position 

and restarting the IDU, this may result in damage to the ODU and inability to communicate with the ODU.

 

2.

 

Apply

 

power

 

to

 

the

 

IDU.

  

After

 

boot

up

 

verify

 

ODU

 

is

 

detected

 

by

 

pushing

 

the

 

ODU

 

touch

 

screen

 

tab

 

to

 

see

 

the

 

ODU

 

status.

 

3.

 

To

 

access

 

the

 

Web

 

UI

 

(the

 

default

 

IP

 

address

 

is

 

192.168.1.10

,

 

log

 

in

 

using

 

admin

/

admin

.

  

4.

 

Select

 

Preset

 

1

 

(default

 

ENG)

 

which

 

is

 

set

 

for

 

SD

SDI

 

and

 

embedded

 

audio.

  

5.

 

Select

 

the

 

RF

 

channel

 

you

 

want

 

to

 

use

 

and

 

press

 

the

 

transmit/standby

 

button

 

to

 

start

 

RF

 

transmission.

  

6.

 

To

 

create,

 

save

 

or

 

copy

 

custom

 

presets,

 

RF

 

channels

 

or

 

other

 

advanced

 

setting

 

refer

 

the

 

user

 

manual.

   

7.

 

Please

 

note

 

that

 

the

 

user

 

manual

 

can

 

be

 

accessed

 

from

 

the

 

Web

 

UI

 

Support

 

tab.

 

 

Note:

  

For

 

Cellular

 

(CNG)

 

and

 

Satellite

 

(SNG)

 

mode

 

refer

 

to

 

the

 

user

 

manual

 

for

 

instructions

 

on

 

how

 

to

 

get

 

these

 

modes

 

configured.

 

 

If

 

you

 

have

 

any

 

questions,

 

please

 

call

 

978.671.5995

 

 